Related Experiment Video
Updated: Aug 18, 2026

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Abnormal subendocardial blood flow in pressure overload hypertrophy is associated with pacing-induced subendocardial
K Nakano1, W J Corin, J F Spann
1Department of Medicine, Medical University of South Carolina, Charleston 29425.
Abstract:
To detect the functional significance of subendocardial hypoperfusion in the pressure-overloaded left ventricle, we studied subendocardial and subepicardial function and subendocardial and subepicardial blood flow simultaneously in seven dogs with left ventricular hypertrophy (left ventricle/body weight ratio, 7.2 g/kg) produced by chronic aortic banding. Seven normal dogs served as controls. Subendocardial and subepicardial segment lengths were measured by ultrasonic dimension gauges, and myocardial blood flow was measured with radioactive microspheres. Atrial pacing (180-200 beats/min for 5 minutes) was used to produce a chronotropic stress. In dogs with left ventricular hypertrophy, the subendocardial blood flow failed to increase during pacing compared with the baseline state (1.21 +/- 0.17 vs. 1.22 +/- 0.17 ml/min/g). Subendocardial shortening fraction deteriorated with pacing stress (before pacing, 30.6 +/- 3.9%; after pacing, 24.2 +/- 3.7%; p less than 0.001). In controls, subendocardial blood flow increased from 1.32 +/- 0.19 to 1.80 +/- 0.19 ml/min/g during pacing, and shortening fraction was preserved (before pacing, 25.5 +/- 3.9%; after pacing, 25.9 +/- 3.3%). Subepicardial blood flow in dogs with hypertrophy increased from 1.54 +/- 0.24 to 2.32 +/- 0.34 ml/min/g, and subepicardial shortening fraction was maintained (before pacing, 10.4 +/- 1.0%; after pacing, 10.5 +/- 1.2%) as it was in controls (subepicardial blood flow, from 1.27 +/- 0.18 to 2.12 +/- 0.17 ml/min/g; shortening fraction, from 16.6 +/- 2.5% to 15.5 +/- 2.2%). We conclude that, with pacing stress in pressure-overload hypertrophy, subendocardial blood flow failed to increase. This abnormality corresponded with a deterioration in subendocardial contractile function.
Related Concept Videos
Pathophysiology of Cardiac Performance
Pathophysiology of Heart Failure
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Mitral Regurgitation I: Introduction
Heart Failure II: Pathophysiology
Cardiomyopathy III: Hypertrophic Cardiomyopathy