Background:
Health Care Providers (HCPs) report that manual techniques of intravascular fluid resuscitation are commonly used during pediatric shock management. The optimal pediatric fluid resuscitation technique is currently unknown. We sought to determine HCP test-retest reliability (repeatability) and inter-subject variability of fluid resuscitation performance outcomes to inform the design of future studies.
Methods:
Fifteen consenting HCPs from McMaster Children's Hospital, in Hamilton, Canada participated in this single-arm interventional trial. Participants were oriented to a non-clinical model representing a 15 kg toddler, which incorporated a 22-gauge IV catheter. Following a standardization procedure, participants administered 600 mL (40 mL/kg) of saline to the simulated child under emergency conditions using prefilled 60-mL syringes. Each participant completed 5 testing trials. All testing was video recorded, with fluid administration time outcome data (in seconds) extracted from trial videos by two blinded outcome assessors. Data describing catheter dislodgement events, volume of saline effectively delivered, and participant demographics were also collected. The primary outcome of fluid administration time test-retest reliability was analyzed by one-way analysis of variance (ANOVA) and intra-class correlation (ICC), with good reliability defined as ICC > 0.70.
Results:
Differences in HCP fluid administration times are attributable to inter-subject variability rather than intra-subject variability based on one-way ANOVA analysis, F (14,60) = 43.125; p < 0.001. Test-retest reliability of subjects was excellent with ICC = 0.97 (95% CI: 0.95-0.99); p < 0.001.
Conclusions:
Findings demonstrate excellent test-retest reliability of HCP fluid resuscitation performance in a setting involving a non-clinical model. Investigators can justify a single evaluation of HCP performance in future studies.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of blood pressure in brachial artery(two-step method)
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.