Related Experiment Video
Updated: Apr 22, 2026

Single-port Non-liposuction Endoscopic Axillary Lymph Node Dissection in Breast Cancer Surgery
Published on: April 3, 2026
Clinical significance of the axillary arch in sentinel lymph node biopsy
Won Ho Kil1, Jeong Eon Lee1, Seok Jin Nam1
1Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Purpose:
The axillary arch is an anomalous muscle that is not infrequently encountered during axillary sentinel lymph node biopsy (SLNB) of breast cancer patients. In this study, we aimed to investigate how often the axillary arch is found during SLNB and whether it affects the intraoperative sentinel lymph node (SLN) identification rate.
Methods:
We retrospectively analyzed the correlation between the presence of the axillary arch and the SLN sampling failure rate during SLNB in 1,069 patients who underwent axillary SLNB for invasive breast cancer.
Results:
Of 1,069 patients who underwent SLNB, 79 patients (7.4%) had the axillary arch present. The SLNB failure rate was high when the patient's body mass index was ≥25 (p=0.026), when a single SLN mapping technique was used (p=0.012), and when the axillary arch was present (p<0.001). These three factors were also found to be statistically significant by multivariate analysis, and of these three factors, presence of the axillary arch most significantly increased the SLNB failure rate (hazard ratio, 10.96; 95% confidence interval, 4.42-27.21; p<0.001). Additionally, if the axillary arch was present, the mean operative time of SLNB was 20.8 minutes, compared to 12.5 minutes when the axillary arch was not present (p<0.001). If the axillary arch was present, the SLN was often located in a high axillary region (67%) rather than in a general low axillary location.
Conclusion:
The axillary arch was found to be a significant factor affecting intraoperative SLN failure rate. It is necessary to keep in mind that carefully checking the high axillar region during SLNB in breast cancer patients with the axillary arch is important for reducing SLN sampling failure.
More Related Videos
07:51The Application of 1% Methylene Blue Dye As a Single Technique in Breast Cancer Sentinel Node Biopsy
Published on: June 1, 2019
03:07Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial
Published on: August 19, 2025
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Detailed Structure and Function of Lymph Nodes
From a histological perspective, lymph nodes can be split into two main areas: the superficial cortex and the deep medulla. The outer cortex is populated by dendritic cells, macrophages, and B lymphocytes, which are densely packed into follicles. When these B-lymphocytes are presented...