Atmospheric temperature measurements at altitudes of 5-30 km with a double-grating-based pure rotational Raman lidar
Abstract:
A pure rotational Raman (PRR) lidar based on a second-harmonic generation Nd:YAG laser is built for measuring the atmospheric temperature at altitudes of 5-30 km. A double-grating polychromator is designed to extract the wanted PRR signals and suppress the elastically backscattered light. Measured examples present the overall lidar performance. For the 1-h integrated lidar temperature profiles, the 1σ statistical uncertainty is less than 0.5 K up to ∼17 km, while it does not exceed 2 K at altitudes of 17-26.3 km. Based on 38 nights of high-quality lidar temperature data, the temperature variability is studied. It is found that the variability differs between the nights with inversion layer and those without it. On the nights without inversion layer, the local hour-to-hour temperature variability was mostly less than 1 K at altitudes of 5-17 km. At altitudes of 17-23 km, it grew to 1.2-2.4 K. On the nights with inversion layer, in the middle and upper troposphere, the significant variability was found to occur only at the inversion-layer altitudes. At other tropospheric altitudes off the inversion layer, the variability was generally less than 1 K. The statistical results indicate that the temperature variability mostly was stronger in the presence of inversion layer than in its absence.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...