Related Experiment Video
Updated: Apr 21, 2026

Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Noncontact monitoring breathing pattern, exhalation flow rate and pulse transit time
Abstract:
We present optical imaging-based methods to measure vital physiological signals, including breathing frequency (BF), exhalation flow rate, heart rate (HR), and pulse transit time (PTT). The breathing pattern tracking was based on the detection of body movement associated with breathing using a differential signal processing approach. A motion-tracking algorithm was implemented to correct random body movements that were unrelated to breathing. The heartbeat pattern was obtained from the color change in selected region of interest (ROI) near the subject's mouth, and the PTT was determined by analyzing pulse patterns at different body parts of the subject. The measured BF, exhaled volume flow rate and HR are consistent with those measured simultaneously with reference technologies (r = 0.98, for HR; r = 0.93, for breathing rate), and the measured PTT difference (30-40 ms between mouth and palm) is comparable to the results obtained with other techniques in the literature. The imaging-based methods are suitable for tracking vital physiological parameters under free-living condition and this is the first demonstration of using noncontact method to obtain PTT difference and exhalation flow rate.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes and Capacities I
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:

