Related Experiment Video
Updated: Apr 21, 2026

Synthesis of pH Dependent Pyrazole, Imidazole, and Isoindolone Dipyrrinone Fluorophores using a Claisen-Schmidt Condensation Approach
Published on: June 10, 2021
Tunable trimers: using temperature and pressure to control luminescent emission in gold(I) pyrazolate-based trimers
Christopher H Woodall1, Sara Fuertes, Christine M Beavers
1Department of Chemistry, University of Bath, Bath BA2 7AY (UK).
Abstract:
A systematic investigation into the relationship between the solid-state luminescence and the intermolecular Au⋅⋅⋅Au interactions in a series of pyrazolate-based gold(I) trimers; tris(μ2 -pyrazolato-N,N')-tri-gold(I) (1), tris(μ2 -3,4,5- trimethylpyrazolato-N,N')-tri-gold(I) (2), tris(μ2 -3-methyl-5-phenylpyrazolato-N,N')-tri-gold(I) (3) and tris(μ2 -3,5-diphenylpyrazolato-N,N')-tri-gold(I) (4) has been carried out using variable temperature and high pressure X-ray crystallography, solid-state emission spectroscopy, Raman spectroscopy and computational techniques. Single-crystal X-ray studies show that there is a significant reduction in the intertrimer Au⋅⋅⋅Au distances both with decreasing temperature and increasing pressure. In the four complexes, the reduction in temperature from 293 to 100 K is accompanied by a reduction in the shortest intermolecular Au⋅⋅⋅Au contacts of between 0.04 and 0.08 Å. The solid-state luminescent emission spectra of 1 and 2 display a red shift with decreasing temperature or increasing pressure. Compound 3 does not emit under ambient conditions but displays increasingly red-shifted luminescence upon cooling or compression. Compound 4 remains emissionless, consistent with the absence of intermolecular Au⋅⋅⋅Au interactions. The largest pressure induced shift in emission is observed in 2 with a red shift of approximately 630 cm(-1) per GPa between ambient and 3.80 GPa. The shifts in all the complexes can be correlated with changes in Au⋅⋅⋅Au distance observed by diffraction.
More Related Videos
06:06A Simple Dewar/Cryostat for Thermally Equilibrating Samples at Known Temperatures for Accurate Cryogenic Luminescence Measurements
Published on: July 19, 2016
06:08Time-resolved Photophysical Characterization of Triplet-harvesting Organic Compounds at an Oxygen-free Environment Using an iCCD Camera
Published on: December 27, 2018
Related Concept Videos
Photoluminescence: Applications
Variables Affecting Phosphorescence and Fluorescence
Fluorescence and Phosphorescence: Instrumentation
Photoluminescence: Fluorescence and Phosphorescence
A pair of electrons in a...