Related Experiment Video
Updated: Apr 21, 2026

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
MR venography in patients with multiple sclerosis and correlation with clinical and MRI parameters
Background And Purpose:
Multiple sclerosis (MS) has been associated with chronic cerebrospinal venous insufficiency. We aim to evaluate the correlation between extracranial veins stenosis evaluated with MR venography (MRV) and clinical/MR parameters of MS.
Methods:
In 29 consecutive MS patients we performed a standard brain MRI protocol, completed by the evaluation of extra-cerebral venous system using a phase-contrast and a Volumetric Interpolated Breath Hold Examination (VIBE) sequence before and after gadolinium. The T2-proton density images were used to calculate the lesion volume. The jugular veins were evaluated qualitatively (in terms of presence and severity of stenoses) and quantitatively (degree of stenosis). The phase-contrast images were analyzed to calculate the average and peak velocity in the internal jugular veins.
Results:
Postcontrast VIBE successfully showed the jugular veins in all the subjects. T2-lesion-volume was 8.2 [4.6] cm³. A stenosis of the internal jugular veins > of 50% was observed in 10/29(33%) patients. No significant correlation was observed between T2-lesion-volume and degree-of-stenosis (r = .362, P = .302). No different flow parameters were found in the subgroups of patients with and without stenosis (P = .54).
Conclusions:
In MS the presence/severity of jugular vein stenosis identified with 3T-MRV is not related to MR-visible tissue damage. Moreover no abnormal flow parameters were found in stenosed veins.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Magnetic Resonance Imaging