Related Experiment Video
Updated: Apr 21, 2026

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
[Research on high sensitivity temperature sensor based on Mach-Zehnder interferometer with waist-enlarged fiber
Abstract:
Optical fiber sensing technology is one of the very promising techniques in sensing fields. A high sensitivity high temperature sensor based on inline optical fiber Mach-Zehnder(M-Z) interferometer by using standard single mode fiber with two waist-enlarged bitapers is proposed in the present paper. The waist-enlarged bitapers are considered as couplers, the distance between the two bitapers is the sensing arm. The light in the lead-in fiber core couples into the sensing arms' fiber core and cladding by the first bitaper, and then propagate in them. The phase difference between core mode and cladding mode is produced when the light reaches the second bitaper. Then the second bitaper couples the light into the lead-out single-mode fiber to get the interference spectrum. The sensors with different length were fabricated. The relationship between the sensor length and interference period, and the temperature response of the.sensor were studied by experiments. The results show that the 35 mm long sensor has a high sensitivity of 0.115 nm x degrees C(-1) in the range of 30-400 degrees C. The transmission spectrum of the sensor was also analyzed by the fast Fourier transform. It shows that only LP01 mode and LP08 mode propagate in the sensor. Thesensor has advantages of small size, high precision, and immunity to electromagnetic inteference. In addition, it is of easy fabrication, high signal-to-noise ratio, light weight, and high sensitivity, and could be operated under high temperature. This kind of sensor is a good candidate for high temperature measurement of hot gas, oil and gas well logging and other areas.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...

