Related Experiment Video
Updated: Apr 21, 2026

Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
Published on: March 13, 2026
Hardware-related complications after dorsal plating for displaced distal radius fractures
Abstract:
There has been a trend away from dorsal fixation of distal radius fractures secondary to a historically higher complication rate. However, the literature on low-profile dorsal plates and titanium implants for the treatment of these fractures is limited. The goal of the current study was to evaluate hardware-related complications and removal rates after open reduction and internal fixation of unstable, displaced distal radius fractures using a dorsal approach with a low-profile titanium plate. A single surgeon treated 125 patients with isolated, unstable, dorsally displaced distal radius fractures by open reduction and internal fixation using a low-profile titanium dorsal plating system. A total of 110 patients were followed for a minimum of 1 year, and mean follow-up was 27 months (range, 12-74). Outcomes were assessed radiographically and clinically. Satisfactory alignment was achieved in all cases, and no fracture went on to nonunion. Nine patients (8%) required removal of hardware at an average of 12 months (range, 6-34). Six patients (5%) had evidence of extensor tenosynovitis intraoperatively, but no extensor tendon ruptures were identified. Overall, using the Gartland and Werley score, results were excellent in 82 patients, good in 22 patients, fair in 5 patients, and poor in 1 patient. Six complications accounted for the fair and poor results. The average Disabilities of the Arm, Shoulder and Hand (DASH) score at latest follow-up was 6 (range, 0-25). This series showed that the technique of dorsal plating with a low-profile titanium plate is safe and effective.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
10:36Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Peripheral Artery Disease V: Postoperative Nursing Management