Related Experiment Video
Updated: Apr 21, 2026

A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
An iatrogenic popliteal pseudoaneurysm masked under compartment syndrome of leg
Jahangir Sajjad1, Andrew Coveney2, Abubakr Ahmed2
1Department of Surgery, Cork university Hospital, Cork, Republic of Ireland jsajjad@me.com.
Abstract:
This case describes a 60-year-old gentleman who presented with a pulsating mass behind his knee. Before this, he had a fasciotomy for suspected compartment syndrome of leg following knee arthroscopy, but this failed to resolve his leg symptoms. He was hemodynamically stable on presentation. His left calf was swollen with a circumference of 3 cm greater than right. There was a large pulsating mass palpable in his left popliteal fossa. Distal neurovascular status of the leg was intact. He had a normal cardiovascular, respiratory, abdominal and neurological examination. Ultrasound showed a cystic mass in the popliteal fossa suggestive of aneurysm. CT angiogram demonstrated a 6 × 5 × 4 cm pseudoaneurysm compressing and displacing the left popliteal artery with satisfactory three-vessel run-off. An emergency repair was performed. An arteriotomy was identified at the proximal end of pseudoaneurysm and it was closed with a patch of small saphenous vein. It led to a good clinical outcome.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease V: Postoperative Nursing Management
Aneurysm I: Introduction
Muscles that Move the Leg
Anterior Compartment
The quadriceps femoris, the most visible muscle of the anterior compartment, is integral for leg extension and thigh flexion. It is formed by merging four distinct muscles — the vastus lateralis, vastus medialis, vastus intermedius, and rectus femoris. The quadriceps tendon, a shared tendon of the four quadriceps muscles, is affixed...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Arteries of Lower Limbs