Hyphenation of capillary high-performance ion-exchange chromatography with mass spectrometry using sheath-flow
Sven Kochmann1, Frank-Michael Matysik
1Institute of Analytical Chemistry, University of Regensburg, Universitätsstr. 31, D-93053, Regensburg, Germany.
Rationale:
Mass spectrometry (MS) is an attractive method for extending capillary-size ion chromatography (cHPIC) to create a valuable technique for speciation analysis. For hyphenation, the aqueous effluent of cHPIC has to be transformed into a volatile mixture for MS while preserving analytical concentrations as well as peak shapes during transfer from cHPIC to MS. Finally, the approach should technically be flexible and easy-to-use. A combination of cHPIC and sheath-flow electrospray ionization (ESI)-MS offers to solve all these challenges.
Methods:
cHPIC/sheath-flow-ESI-TOFMS was used in this study for the speciation analysis of various arsenic model compounds. These model compounds were analyzed with different hyphenation setups and configurations of cHPIC/MS and their respective assets and drawbacks were examined and discussed. The parameters (flow rate and composition of sheath liquid) of sheath-flow ESI and their influence on the performance of the spray and the sensitivity of the detector were investigated and compared with those of sheathless ESI.
Results:
Using an injection valve to couple cHPIC and MS was found to be the best method for hyphenation, since it constitutes a flexible and dead-volume-free approach. The investigation of sheath-flow ESI revealed that the flow rate of the sheath liquid has to resemble the flow rate of the IC effluent to ensure a stable spray and that a composition of 2-propanol/water/ammonia at 50:50:0.2 (v/v/v) suits most applications without unilaterally promoting the sensitivity for either organic or inorganic compounds. The optimized setup and conditions were successfully applied to the analysis of a mixture of important arsenic species and used to determine limits of detection of organic and inorganic arsenic species (3.7 µg L(-1) elemental arsenic).
Conclusions:
A method for cHPIC/sheath-flow-ESI-MS was developed. The method was shown to be a valuable tool for speciation and trace analysis. It features no dead volume, fast transfer from IC to MS, only minimal peak-widening, high reproducibility, and the ability to fine-tune the ESI spray for higher sensitivity and stability by adjusting the composition of the sheath-liquid.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
05:45Capillary Electrophoresis-based Hydrogen/Deuterium Exchange for Conformational Characterization of Proteins with Top-down Mass Spectrometry
Published on: June 8, 2021
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Electrophoresis: Overview
There...