Closed Chest Biventricular Pressure-Volume Loop Recordings with Admittance Catheters in a Porcine Model
Published on: May 18, 2021
The relationship between R-wave magnitude and ventricular volume during continuous left ventricular assist device
Libera Fresiello1, Maria Giovanna Trivella2, Arianna Di Molfetta1
1Institute of Clinical Physiology, Section of Rome, National Research Council, Rome, Italy.
Abstract:
The current use of left ventricular assist devices (LVADs) as destination therapy is associated with the clinical need of monitoring patient-pump interaction. To this aim, the present work investigated the possibility of getting useful information about the status of the assisted left ventricle using electrocardiographic (ECG) data. A total of six animals, undergoing Gyro Centrifugal Pump 2 implantation (a new version of Gyro Centrifugal Pump C1E3 [Kyocera Corporation, Kyoto, Japan]) and CircuLite Synergy Micropump (CircuLite, Inc., Saddlebrooke, NJ, USA) in atrio-aortic connection, were analyzed. Data refer to different LVAD speeds with consequently different levels of ventricular unloading. From ECG signal, the R wave peak was individuated together with the corresponding left ventricular volume. Then on both signals, a moving average analysis was performed to reduce the effect of the ventilation. A regression and correlation analysis performed on the two resulting signals evidenced that the R wave peak and the ventricular volume are strictly related. Specifically, any change of LVAD speed, inducing a change in ventricular volume, is associated with a change in R wave peak value. The present work is a first step in investigating the usefulness of the ECG signal during LVAD therapy, for the monitoring of mechanical parameters of the heart such as the ventricular volumes. The correlation found between the ECG and the ventricular volume can be a promising starting point for possible future noninvasive LVAD patient monitoring.
More Related Videos
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...