Related Experiment Video
Updated: Apr 21, 2026

How to Build a Laser Speckle Contrast Imaging LSCI System to Monitor Blood Flow
Published on: November 11, 2010
Assessment of Short-Term Changes in Optic Nerve Head Hemodynamics in Hyperoxic Conditions with Laser Speckle
Yukihiro Shiga1, Marika Sato1, Kazuichi Maruyama1
1a Department of Ophthalmology , Tohoku University Graduate School of Medicine , Miyagi , Japan .
Purpose:
To evaluate laser speckle flowgraphy (LSFG) measurements of the optic nerve head (ONH) blood flow (BF) response to hyperoxia.
Methods:
This prospective study included 30 eyes of 30 healthy volunteers (mean age: 28.5 ± 4.0, male:female = 13:17). The testing protocol had three phases: in the baseline phase, subjects breathed room air; in the hyperoxic phase, they breathed pure oxygen (6 L/min) for 15 min; and in the recovery phase, they were room air for 15 min. LSFG measurements of mean blur rate (MBR), which represents ONH BF, were taken every minute. The MBR ratio in the hyperoxic and recovery phases was calculated with reference to this baseline. Clinical parameters, including systemic blood pressure, pulse rate, and saturation of pulse-oximetry oxygen (SpO2), were measured every 5 min.
Results:
SpO2 increased significantly during hyperoxia (97.3 ± 1.1% to 99.3 ± 0.7%, p < 0.001). While clinical parameters were similar in hyperoxia and baseline, MBR decreased significantly after 2 min of hyperoxia (90.8 ± 12.6%, p = 0.02), stayed steady throughout hyperoxia (mean: 89.5 ± 10.8%, p range: <0.001-0.04) compared with baseline, and returned to baseline 1 min after recovery (93.7 ± 10.3%, p = 0.25). A linear regression using a third-order polynomial fitting curve analysis revealed that the time to reach minimum MBR was 7.78 min (adjusted R(2 )= 0.87).
Conclusion:
LSFG could effectively assess ONH BF changes during hyperoxia.