Related Experiment Video
Updated: Apr 21, 2026

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Implementation of Bubble CPAP in a Rural Ugandan Neonatal ICU
Ryan M McAdams1, Anna B Hedstrom2, Robert M DiBlasi3
1Department of Pediatrics, University of Washington, Seattle, Washington. Department of Pediatrics, Seattle Children's Hospital, Seattle, Washington. mcadams@uw.edu.
Background:
Respiratory distress is a leading cause of neonatal death in low-income and middle-income countries. CPAP is a simple and effective respiratory support modality used to support neonates with respiratory failure and can be used in low-income and middle-income countries. The goal of this study was to describe implementation of the Silverman-Andersen respiratory severity score (RSS) and bubble CPAP in a rural Ugandan neonatal NICU. We sought to determine whether physicians and nurses in a low-income/middle-income setting would assign similar RSS in neonates after an initial training period and over time.
Methods:
We describe the process of training NICU staff to use the RSS to assist in decision making regarding initiation, titration, and termination of bubble CPAP for neonates with respiratory distress. Characteristics of all neonates with respiratory failure treated with bubble CPAP in a rural Ugandan NICU from January to June 2012 are provided.
Results:
Nineteen NICU staff members (4 doctors and 15 nurses) received RSS training. After this, the Spearman correlation coefficient for respiratory severity scoring between doctor and nurse was 0.73. Twenty-one infants, all < 3 d of age, were treated with CPAP, with 17 infants starting on the day of birth. The majority of infants (16/21, 76%) were preterm, 10 (48%) were <1,500 g (birthweight), and 13 (62%) were outborn. The most common diagnoses were respiratory distress syndrome (16/21, 76%) and birth asphyxia (5/21, 24%). The average RSS was 7.4 ± 1.3 before starting CPAP, 5.2 ± 2.3 after 2-4 h of CPAP, 4.9 ± 2.7 after 12-24 h of CPAP, and 3.5 ± 1.9 before CPAP was discontinued. Duration of treatment with CPAP averaged 79 ± 43 h. Approximately half (11/21, 52%) of infants treated with CPAP survived to discharge.
Conclusions:
Implementing bubble CPAP in a low-income/middle-income setting is feasible. The RSS may be a simple and useful tool for monitoring a neonate's respiratory status and for guiding CPAP management.
More Related Videos
11:27A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
08:58Development of a Neonatal Piglet Acute Lung Injury Model Recreating the Early Environment of Preterm Infant Lungs
Published on: October 31, 2025
Related Concept Videos
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...