[Low-concentration contrast material for dual-source computed tomography coronary angiography by a combination of
Yongjie Wu1, Minwen Zheng1, Hongliang Zhao1
1Department of Radiology, Xijing Hospital, Affiliated to the Fourth Military Medical University, Xi'an 710032, China.
Objective:
To assess the impact of low concentration contrast media on the degree of vascular enhancement, image quality and radiation dose in coronary CT angiography (cCTA) studies when using a combination of iterative reconstruction and low tube voltage.
Methods:
120 patients who underwent cCTA were randomly divided into two groups. The patients in group A received iopromide 370 were scanned using the conventional tube output, and images were reconstructed using filtered back projection (FBP). The patients in group B received iodixanol 270 were scanned using the low tube output, and images were reconstructed using iterative reconstruction technique (SAFIRE, Siemens Healthcare). CT attenuation was measured in the coronary arteries, great arteries, interventricular septum and left ventricular cavity. Noise, subjective image quality scores and effective radiation dose were compared between the two groups.
Results:
There was no significant difference in the mean CT attenuation achieved, image noise and mean image quality score at each anatomic site between iomeprol 270 group and iopromide 370 group. The effective radiation dose were 0.44 ± 0.25 mSv and 0.94 ± 0.42 mSv for iomeprol 270 and iopromide 370 in low weight subgroups, and 1.17 ± 0.30 mSv and 2.37 ± 0.66 mSv in high weight subgroups, respectively, reflecting dose savings of 53.2% (P < 0.01) and 50.6% (P < 0.01), respectively.
Conclusion:
The results demonstrate that with a combination of iterative reconstruction and a low tube voltage , a low iodine concentration of 270 mgI/ml still improves the contrast enhancement without impairing image quality, as well as significantly lowers effective radiation dose.
More Related Videos
05:32Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation I: X-ray and CT