Determination of sterigmatocystin in grain using gas chromatography-mass spectrometry with an on-column injector
1Faculty of Agriculture, Shinshu University, 8304 Minami-minowa-Mura, Kamiina, Nagano, 399-4598, Japan.
Abstract:
Sterigmatocystin (STC) is a mycotoxin produced by several species of Aspergillus and other fungi. STC is a precursor of the carcinogen aflatoxin B1 and exerts carcinogenic, teratogenic, and mutagenic effects. A reliable GC-MS-based analytical method using on-column injection was developed and validated to determine STC content in grain. In this method, STC was extracted with acetonitrile (84%), and the filtered extract was diluted with phosphate buffer before immunoaffinity column (IAC) cleanup. After elution and N2 evaporation, the sample containing STC was dissolved in acetone and injected into the GC-MS system without derivatization. Separation of STC was carried out by a capillary column (0.25 mm i.d.×30 m, 0.25 μm) with a deactivated pre-column (0.53 mm i.d.×0.6 m). The matrix effect was investigated in maize, wheat, and rice, and an insignificant matrix effect was observed after IAC cleanup. The calibration curve was linear in the range of 20-300 pg (equivalent to 8-120 μg/kg in grain) with a coefficient of determination (R2) of 0.999, and the relative standard deviation of repeatability (RSDr) was less than 10 %. The limit of detection (LOD) of the method was 6 pg (equivalent to 2.4 μg/kg in grain), and the limit of quantification (LOQ) was 20 pg (equivalent to 8 μg/kg). The method described in this report is sensitive, reliable, and can be used to monitor STC contamination in grain.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:10Untargeted Liquid Chromatography-Mass Spectrometry-Based Metabolomics Analysis of Wheat Grain
Published on: March 13, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...