Related Experiment Video
Updated: Apr 20, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Development of a screening tool for sleep disordered breathing in children using the phone Oximeter™
Ainara Garde1, Parastoo Dehkordi1, Walter Karlen1
1Electrical and Computer Engineering in Medicine Group, The University of British Columbia and BC Children's Hospital, Vancouver, British Columbia, Canada.
Insights
A new smartphone-integrated device effectively screens children for sleep disordered breathing (SDB) by analyzing blood oxygen saturation (SpO2) and pulse rate variability (PRV), offering a portable at-home alternative to polysomnography.
Area of Science:
- Pediatric Sleep Medicine
- Biomedical Engineering
- Cardiorespiratory Monitoring
Background:
- Sleep disordered breathing (SDB) in children can cause significant health issues, including developmental delays.
- Diagnosing SDB traditionally requires polysomnography (PSG), a complex and resource-intensive laboratory test.
Purpose of the Study:
- To develop and validate a smartphone-based device for identifying SDB in children.
- To combine SpO2 and PRV analysis for improved SDB detection.
Main Methods:
- 160 children referred for PSG were enrolled.
- A smartphone-integrated pulse oximeter recorded SpO2 and photoplethysmogram (PPG) overnight.
- SpO2 variability and PRV were analyzed to identify SDB indicators.
Main Results:
- SpO2 variability and low-frequency spectral power were significantly higher in children with SDB (p<0.01).
- PRV analysis indicated increased sympathetic activity in SDB patients.
- A classifier combining SpO2 and PRV achieved 88% area under the ROC curve, outperforming SpO2 alone (82%).
Conclusions:
- The Phone Oximeter, using SpO2 and PRV, demonstrates potential as an improved, portable screening tool for SDB in children.
- This technology enables convenient at-home monitoring and can be used for multi-night assessments.
Background:
Sleep disordered breathing (SDB) can lead to daytime sleepiness, growth failure and developmental delay in children. Polysomnography (PSG), the gold standard to diagnose SDB, is a highly resource-intensive test, confined to the sleep laboratory.
Aim:
To combine the blood oxygen saturation (SpO2) characterization and cardiac modulation, quantified by pulse rate variability (PRV), to identify children with SDB using the Phone Oximeter, a device integrating a pulse oximeter with a smartphone.
Methods:
Following ethics approval and informed consent, 160 children referred to British Columbia Children's Hospital for overnight PSG were recruited. A second pulse oximeter sensor applied to the finger adjacent to the one used for standard PSG was attached to the Phone Oximeter to record overnight pulse oximetry (SpO2 and photoplethysmogram (PPG)) alongside the PSG.
Results:
We studied 146 children through the analysis of the SpO2 pattern, and PRV as an estimate of heart rate variability calculated from the PPG. SpO2 variability and SpO2 spectral power at low frequency, was significantly higher in children with SDB due to the modulation provoked by airway obstruction during sleep (p-value <0.01). PRV analysis reflected a significant augmentation of sympathetic activity provoked by intermittent hypoxia in SDB children. A linear classifier was trained with the most discriminating features to identify children with SDB. The classifier was validated with internal and external cross-validation, providing a high negative predictive value (92.6%) and a good balance between sensitivity (88.4%) and specificity (83.6%). Combining SpO2 and PRV analysis improved the classification performance, providing an area under the receiver operating characteristic curve of 88%, beyond the 82% achieved using SpO2 analysis alone.
Conclusions:
These results demonstrate that the implementation of this algorithm in the Phone Oximeter will provide an improved portable, at-home screening tool, with the capability of monitoring patients over multiple nights.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Sleep Apnea
The condition is more prevalent among...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...