Related Experiment Video
Updated: Apr 20, 2026

10:42
Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
6.7K
Non-collinear upconversion of infrared light
Optics Express
|November 18, 2014
Summary
A new theory models mid-infrared upconversion imaging, enabling spectral and spatial information extraction. This general theory accurately predicts upconverted light fields, verified experimentally for enhanced spectroscopy and hyperspectral imaging applications.
Area of Science:
- Nonlinear Optics
- Spectroscopy
- Imaging Science
Background:
- Two-dimensional mid-infrared upconversion imaging offers unique spectral and spatial data.
- Extracting this information requires complex models accounting for non-collinear interactions.
Purpose of the Study:
- To derive a general theoretical framework for upconverted light fields.
- To enable accurate spectral and spatial information retrieval from mid-infrared upconversion images.
Main Methods:
- Developed a general theory for the far field of upconverted light from two interacting fields in a nonlinear crystal.
- Experimental verification using incoherent radiation.
Main Results:
- The derived theory accurately predicts the behavior of upconverted light.
- Experimental validation confirmed theoretical predictions.
- The model shows good agreement with previously published data.
Conclusions:
- The general theory provides a robust method for analyzing mid-infrared upconversion imaging.
- This work facilitates advanced mid-infrared spectroscopy and hyperspectral imaging.
- The findings pave the way for more precise spectral and spatial information extraction.
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
7.7K
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
7.7K
IR Absorption Frequency: Hybridization
1.7K
Hydrocarbons such as alkanes, alkenes, and alkynes show characteristic C–H stretching absorption bands. These IR stretching frequencies depend on the hybridization of the involved carbon atom and can be explained in terms of the s character of each hybridized atomic orbital.
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that...
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that...
1.7K
IR Frequency Region: X–H Stretching
1.9K
In IR spectroscopy, signals produced by the X−H bonds (such as C−H, O−H, or N−H) can be observed in the frequency range of 2700–4000 cm–1. The C−H stretching vibration forms sharp bands in the region 2850–3000 cm–1. The presence of the O−H stretching vibration leads to the forming of an absorption band in the frequency range 3650–3200 cm−1. At the same time, N−H stretching can be confirmed by absorption bands in...
1.9K
IR Spectrometers
3.6K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
3.6K
IR Spectrum
3.5K
When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
3.5K
Super-resolution Fluorescence Microscopy
14.9K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
14.9K

