Related Experiment Video
Updated: Apr 20, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Adaptation of contrast injection protocol to tube potential for cardiovascular CT
Yajuan Wang1, Michael Bolen, Gregg Sydow
11 Informatics Research and Strategy, Radiology and Interventional, Bayer HealthCare Medical Care, Indianola, PA.
Objective:
The purpose of this study was to investigate and validate adaptation of a cardiovascular CT angiography contrast injection protocol for lower tube potential.
Materials And Methods:
Eighty-three patients evaluated for thoracic aortic disease with a 256-MDCT scanner were imaged at 120 kV (group 1) or 100 kV (group 2) with the same contrast protocol (90 mL iopromide 370 mg I/mL at 3.5 mL/s). A pharmacokinetic model was validated and used to simulate aortic attenuation in group 2 patients with 20%, 33%, and 44% reduction in contrast volume. A 44% volume reduction was applied to 50 additional patients who underwent imaging at 100 kV (group 3). Patient characteristics, scanning and radiation parameters, and objective and subjective image indexes were compared among groups.
Results:
Group 2 patients had higher mean aortic blood attenuation (399±61 HU) than group 1 patients (281±48 HU) (p<0.001) but similar image noise. Group 3 and group 1 patients had similar mean aortic attenuation and noise. Subjective assessment of image quality indicated that group 3 and group 1 had comparable percentages of images with good or excellent diagnostic confidence scores (reader 1, 98% vs 96%; reader 2, 96% vs 96%).
Conclusion:
Lower tube potential (100 kV) for cardiothoracic CT could be accompanied by a 44% reduction in contrast volume with satisfactory aortic blood-pool attenuation in most patients. More personalized adaptation of the contrast protocol that takes into account patient characteristics and tube potential is necessary to ensure sufficient contrast enhancement for all patients.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...