Error analysis of cine phase contrast MRI velocity measurements used for strain calculation
Elisabeth R Jensen1, Duane A Morrow1, Joel P Felmlee2
1Motion Analysis Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN 55905 USA.
Abstract:
Cine Phase Contrast (CPC) MRI offers unique insight into localized skeletal muscle behavior by providing the ability to quantify muscle strain distribution during cyclic motion. Muscle strain is obtained by temporally integrating and spatially differentiating CPC-encoded velocity. The aim of this study was to quantify CPC measurement accuracy and precision and to describe error propagation into displacement and strain. Using an MRI-compatible jig to move a B-gel phantom within a 1.5 T MRI bore, CPC-encoded velocities were collected. The three orthogonal encoding gradients (through plane, frequency, and phase) were evaluated independently in post-processing. Two systematic error types were corrected: eddy current-induced bias and calibration-type error. Measurement accuracy and precision were quantified before and after removal of systematic error. Through plane- and frequency-encoded data accuracy were within 0.4 mm/s after removal of systematic error - a 70% improvement over the raw data. Corrected phase-encoded data accuracy was within 1.3 mm/s. Measured random error was between 1 to 1.4 mm/s, which followed the theoretical prediction. Propagation of random measurement error into displacement and strain was found to depend on the number of tracked time segments, time segment duration, mesh size, and dimensional order. To verify this, theoretical predictions were compared to experimentally calculated displacement and strain error. For the parameters tested, experimental and theoretical results aligned well. Random strain error approximately halved with a two-fold mesh size increase, as predicted. Displacement and strain accuracy were within 2.6 mm and 3.3%, respectively. These results can be used to predict the accuracy and precision of displacement and strain in user-specific applications.
More Related Videos
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
09:29Using Digital Image Correlation to Characterize Local Strains on Vascular Tissue Specimens
Published on: January 24, 2016
Related Concept Videos
Three-Dimensional Analysis of Strain
Measurements of Strain
Mohr's Circle for Plane Strain
Mohr's circle visually represents the strain states under various conditions, which is essential for...
Transformation of Plane Strain
Under plane strain conditions, typical for members where one dimension significantly exceeds the others, deformations and resultant strains are...
True Stress and True Strain
In contrast, true stress offers a more precise portrayal. It is computed by dividing the...