Related Experiment Video
Updated: Apr 20, 2026

Synthesis and Performance Evaluations of ZnCoS/ZnCdS with Twin Crystal Structure for Multifunctional Redox Photocatalysis in Energy Applications
Published on: July 25, 2025
A multisyringe flow-based system for kinetic-catalytic determination of cobalt(II)
Laura Chaparro1, Laura Ferrer2, Luz Leal3
1Renewable Energy and Environmental Protection Department, Advanced Materials Research Center (CIMAV), Miguel de Cervantes 120, Complejo Industrial Chihuahua, Chihuahua, Chih. 31109, Mexico; Group of Analytical Chemistry, Automation and Environment, University of the Balearic Islands, Carretera de Valldemossa Km 7.5, E-07122 Palma de Mallorca, Spain.
Abstract:
A kinetic-catalytic method for cobalt determination based on the catalytic effect of cobalt(II) on the oxidative coupling of 1,2-dihydroxyanthraquinone (alizarin) was automated exploiting multisyringe flow injection analysis (MSFIA). The proposed method was performed at pH 9.2, resulting in a discoloration process in the presence of hydrogen peroxide. The fixed-time approach was employed for analytical signal measurement. The spectrophotometric detection was used exploiting a liquid waveguide capillary cell (LWCC), of 1m optical length at 465 nm. The optimization was carried out by a multivariate approach, reaching critical values of 124 µmol L(-1) and 0.22 mol L(-1) for alizarin and hydrogen peroxide, respectively, and 67°C of reagent temperature. A sample volume of 150 µL was used allowing a sampling rate of 30h(-1). Under optimal conditions, calibration curve was linear in the range of 1-200 µg L(-1) Co, achieving a DL of 0.3 µg L(-1) Co. The repeatability, expressed as relative standard deviation (RSD) was lower than 1%. The proposed analytical procedure was applied to the determination of cobalt in cobalt gluconate and different forms of vitamin B12, cyanocobalamin and hydroxicobalamin with successful results showing recoveries around 95%.
Related Concept Videos
Controlled-Current Coulometry: Overview
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Coulometry: Overview
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Complexometric EDTA Titration Curves
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...

