Related Experiment Video
Updated: Apr 20, 2026

Author Spotlight: Technologies and Challenges in Elemental Analysis of Food Samples
Published on: December 22, 2023
A new Am-Be PGNAA setup for element determination in aqueous solution
Ling Yongsheng1, Jia Wenbao1, Hei Daqian2
1Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China; Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Suzhou 215021, China.
Abstract:
A new prompt-gamma neutron activation analysis (PGNAA) setup has been designed for element determination in aqueous solution with a 300 mCi 241Am-Be neutron source and a 4in.×3in. (diameter×height) BGO detector, uncooled. A polyethylene cylindrical sample container approximately 40cm in outer radius and 80cm in height was used. To reduce the neutron dose in the detector, a block of 5cm thickness Li2CO3 was placed between the source and the detector for separation, but no gamma-blocker was used. By adjusting the position of the detector and optimizing the geometrical conditions of the setup, the element detection limit with a low activity neutron source was further improved. This methodology was checked by simulations with chlorine, mercury and cadmium determination and by experiments with chlorine determination in aqueous samples. The results show a good linear relationship between chlorine concentration and the count of its characteristic peak, and the detection limit of chlorine can reach 41.7mg/L with a collection time of 3600s for each spectrum. Additionally, a linear relationship was identified between mercury concentration and the count of its characteristic peak, but for cadmium, a non-linear relationship was observed in the simulations.
More Related Videos
11:04Ion Mobility-Mass Spectrometry Techniques for Determining the Structure and Mechanisms of Metal Ion Recognition and Redox Activity of Metal Binding Oligopeptides
Published on: September 7, 2019
07:54Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Qualitative Analysis
For instance, group IV...
Washing, Drying, and Ignition of Precipitates
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Overview
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...