Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

5.8K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
5.8K
Linearization and Approximation01:26

Linearization and Approximation

215
Linearization is a mathematical technique used to approximate complex, nonlinear functions with simpler linear models in the vicinity of a chosen reference point. The method is based on the idea that, although a function may be difficult to evaluate exactly, its behavior near a specific input value can often be closely approximated by the tangent line at that point. This approach is particularly useful when small deviations from a known value are involved.Consider the square root function, for...
215
Residuals and Least-Squares Property01:11

Residuals and Least-Squares Property

9.9K
The vertical distance between the actual value of y and the estimated value of y. In other words, it measures the vertical distance between the actual data point and the predicted point on the line
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
9.9K
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

1.5K
This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
1.5K
Improving Translational Accuracy02:07

Improving Translational Accuracy

3.8K
3.8K
Improving Translational Accuracy02:07

Improving Translational Accuracy

15.7K
Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
15.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Learning-based non-linear registration robust to MRI-sequence contrast.

Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition·2026
Same author

Longitudinal FreeSurfer with non-linear subject-specific template improves sensitivity to cortical thinning.

Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition·2026
Same author

Structural connectome analysis using a graph-based deep model for prediction of non-imaging variables.

Frontiers in neuroscience·2026
Same author

DEEP-LEARNING CORTICAL REGISTRATION GUIDED BY STRUCTURAL AND DIFFUSION MRI AND CONNECTIVITY.

Proceedings. IEEE International Symposium on Biomedical Imaging·2026
Same author

MR software tools for real-time decision making and FOV prescription.

Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition·2026
Same author

Quantitative and Morphometric Measures in the Human Hippocampal Tail Using Ex Vivo Imaging Validated With Histology.

Hippocampus·2026
Same journal

Benchmarking fMRI Denoising Pipelines.

Human brain mapping·2026
Same journal

Modeled Long-Term Effects of Psilocybin on Dynamic Activity and Effective Connectivity of Fronto-Striatal-Thalamic Circuits.

Human brain mapping·2026
Same journal

Intrinsic Functional Architecture Reflects Individual Differences in Passive Working Memory: An Exploratory Resting-State fMRI Study.

Human brain mapping·2026
Same journal

Symptom Overlap and Neurobiological Similarities Between Posttraumatic Stress Disorder and Tinnitus.

Human brain mapping·2026
Same journal

Test-Retest Reliability of Sensorimotor Activity Measured With Spinal Cord fMRI.

Human brain mapping·2026
Same journal

The Human Visual Claustrum Responses to Physical Stimulus Properties and Subjective Content During Movie Viewing.

Human brain mapping·2026
See all related articles

Related Experiment Video

Updated: Apr 20, 2026

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
07:13

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities

Published on: October 27, 2023

1.8K

Multi-modal robust inverse-consistent linear registration.

Christian Wachinger1, Polina Golland, Caroline Magnain

  • 1Department of Electrical Engineering and Computer Science, Computer Science and Artificial Intelligence Lab, Massachusetts Institute of Technology, Cambridge, Massachusetts; Department of Neurology, Massachusetts General Hospital, Boston, Massachusetts, 02114.

Human Brain Mapping
|December 4, 2014
PubMed
Summary
This summary is machine-generated.

This study introduces a robust method for cross-modal image registration, improving accuracy by handling intensity differences. The technique enhances alignment for medical images, even with outliers.

Keywords:
computer-assisted image analysishistologymagnetic resonance imagingoptical coherence tomographyrigid and affine image alignmentstatistical model

More Related Videos

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

8.6K
Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
02:09

Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function

Published on: April 12, 2024

1.2K

Related Experiment Videos

Last Updated: Apr 20, 2026

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
07:13

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities

Published on: October 27, 2023

1.8K
Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

8.6K
Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
02:09

Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function

Published on: April 12, 2024

1.2K

Area of Science:

  • Medical image analysis
  • Computational imaging
  • Biomedical engineering

Background:

  • Image registration accuracy degrades with non-compliant image regions.
  • Robust estimation methods improve accuracy but are limited to monomodal registration.
  • Existing techniques struggle with cross-modal image alignment.

Purpose of the Study:

  • To develop a robust and inverse-consistent technique for cross-modal affine image registration.
  • To address limitations of existing methods in handling intensity variations across different imaging modalities.
  • To improve the accuracy of medical image alignment in challenging datasets.

Main Methods:

  • Proposed a novel algorithm derived from a contextual framework for image registration.
  • Utilized a modality-invariant representation based on local entropy estimation and a heteroskedastic noise model.
  • Employed a nonparametric windows density estimator for reliable entropy calculation and derived Gauss-Newton updates.

Main Results:

  • Demonstrated excellent performance of the proposed robust cross-modal registration technique.
  • Successfully aligned datasets containing outliers, including brain tumor, full head, and histology images.
  • The method effectively accounts for differences in local information content in multimodal registration.

Conclusions:

  • The developed technique offers a robust solution for cross-modal affine image registration.
  • The approach significantly improves registration accuracy, particularly in the presence of intensity outliers.
  • This method has broad applicability in aligning diverse medical imaging modalities.