Conductometric determination of ammonium ion with a mobile drop
Pheeraya Jaikang1, Kate Grudpan1, Tinakorn Kanyanee1
1Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; Center of Excellence for Innovation in Analytical Science and Technology, Chiang Mai University, Chiang Mai 50200, Thailand.
Abstract:
A mobile drop based approach was utilized for the conductometric determination of aqueous ammonium ion. A liquid drop was manipulated by gravity to remain or move out of a conductivity measurement zone located on a hydrophobic path. A dilute sulfuric acid drop functioned as a micro gas absorber. Gaseous NH3 was liberated from a sample containing NH4(+) by adding NaOH and purged to flow over the absorber drop. As H(+) in the absorber drop was converted to NH4(+), the conductivity decreased. The rate of the conductivity decrease thus ultimately depended on the NH4(+) concentration in the sample. While the sample could be complex, the liberation of NH3 gas essentially freed the analyte of interest from the matrix and allowed the use of an otherwise nonselective detector. The system was applied to the determination of NH4(+) in some natural waters without prior filtration; the results agreed well with those from a manual indophenol blue method. The approach exhibited a limit of detection (LOD) of 5 μM and a relative standard deviation (RSD) of<5%. The mobile drop gave a constant volume of the gas absorbing solution and provided a cost-effective and simple analytical platform.
More Related Videos
08:05Measurement of the Potential Rates of Dissimilatory Nitrate Reduction to Ammonium Based on 14NH4+/15NH4+ Analyses via Sequential Conversion to N2O
Published on: October 7, 2020
12:47Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Related Concept Videos
Qualitative Analysis
For instance, group IV...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Transport Number
Amperometry: Overview
Common Ion Effect