Bioimpedance and bioreactance methods for monitoring cardiac output
Djordje G Jakovljevic1, Michael I Trenell1, Guy A MacGowan2
1Institute of Cellular Medicine, MoveLab, Newcastle University, Newcastle upon Tyne, United Kingdom; RCUK Centre for Ageing and Vitality, Newcastle University, Newcastle upon Tyne, United Kingdom.
Abstract:
Noninvasive continuous cardiac output monitoring may have wide clinical applications in anaesthesiology, emergency care and cardiology. It can improve outcomes, establish diagnosis, guide therapy and help risk stratification. The present article describes the theory behind the two noninvasive continuous monitoring methods for cardiac output assessment such as bioimpedance and bioreactance. The review discusses the advantages and disadvantages of these methods and highlights the recent method comparison studies. The use of bioimpedance and bioreactance to estimate cardiac output under haemodynamic challenges is also discussed. In particular, the article focuses on performance of the two methods in the assessment of fluid responsiveness using passive leg raising test and cardiac output response to exercise stress testing.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Interfacial Electrochemical Methods: Overview
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Bode Plots Construction
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...