Inversion of peak elution order prevents uniform time alignment of complex liquid-chromatography coupled to mass
Vikram Mitra1, Age Smilde2, Huub Hoefsloot2
1Analytical Biochemistry, Department of Pharmacy, University of Groningen, A. Deusinglaan 1, 9713 AV Groningen, The Netherlands; Netherlands Bioinformatics Centre, Geert Grooteplein 28, 6525 GA Nijmegen, The Netherlands; Netherlands Proteomics Centre, Padualaan 8, 3584 CH Utrecht, The Netherlands.
Abstract:
Retention time alignment is one of the most challenging steps in processing LC-MS datasets of complex proteomics samples acquired within a differential profiling study. A large number of time alignment methods have been developed for accurate pre-processing of such datasets. These methods generally assume that common compounds elute in the same order but they do not test whether this assumption holds. If this assumption is not valid, alignments based on a monotonic retention time function will lose accuracy for peaks that depart from the expected order of the retention time correspondence function. To address this issue, we propose a quality control method that assesses if a pair of complex LC-MS datasets can be aligned with the same alignment performance based on statistical tests before correcting retention time shifts. The algorithm first confirms the presence of an adequate number of common peaks (>∼100 accurately matched peak pairs), then determines if the probability for a conserved elution order of those common peaks is sufficiently high (>0.01) and finally performs retention time alignment of two LC-MS chromatograms. This procedure was applied to LC-MS and LC-MS/MS datasets from two different inter-laboratory proteomics studies showing that a large number of common peaks in chromatograms acquired by different laboratories change elution order with considerable retention time differences.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Chromatographic Methods: Terminology
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences