Related Experiment Video
Updated: Apr 19, 2026

Clinical Application of Single-Surgeon, Three-Port, Laparoscopic Resection for Colorectal Cancer with Natural Orifice Specimen Extraction
Published on: March 24, 2023
Vacuum inversion and securing of distal colonic pseudodiverticula with novel spiked O-rings
Giuseppe Amato1, Tudor Birsan2, Erna Granic2
1Department of General Surgery and Urgency, University of Palermo, Palermo, Italy.
Background:
Diverticular disease is increasingly prevalent in Western societies and is associated with significant morbidity.
Objective:
Two-stage endoscopic device development for inversion and secured ligation of colonic diverticula; first, human cadaver studies were performed to measure forces required for diverticular inversion; second, a novel set of devices (elastic spiked O-ring with delivery system) was tested in animals.
Design:
Prospective, observational study of human cadavers and prospective, interventional study of a porcine model.
Setting:
University hospital pathology laboratory and animal facility.
Intervention:
Full-thickness inversion of the colonic wall with a pipelike delivery instrument to produce an inverted pseudodiverticulum that was secured with a spiked O-ring.
Main Outcome Measurements:
The forces required for diverticular inversion, the secured closure of inverted pseudodiverticula, and the time until necrotic tissue falls off.
Results:
A total of 248 of 248 of cadaveric sigmoid diverticula could be inverted by means of vacuum or forceps. The forces required for inversion ranged from 0.28 to 0.47 N (median, 0.37 N). Twenty-four spiked O-rings were delivered in 6 living pigs to produce 24 inverted pseudodiverticula. One animal died the day after the procedure of a pulmonary thromboembolism. In the remaining 5 pigs, all delivered spiked O-rings remained in place for 7 to 22 days. At necropsy, none of the inverted sites showed signs of perforation but rather full-thickness reparative scarring with ingrowth of connective tissue.
Limitations:
Animal model, stiff pipelike delivery instrument, variations in diverticular location, diameter, and size.
Conclusions:
Endoluminal inversion and securing of colonic diverticula induces tissue necrosis, diverticular sloughing, and full-thickness scarring.
Related Concept Videos
Inflammatory Bowel Disease V: Surgical Management
Here are some common surgical interventions for IBD:
Diverticular Disease of the Colon
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures II: Colonoscopy