Active echo: a new paradigm for ultrasound calibration
This study introduces an active echo (AE) phantom for ultrasound (US) calibration, improving accuracy and reducing user dependency in medical procedures. The AE phantom offers reliable mid-plane identification and automatic segmentation, outperforming traditional methods.
Area of Science:
- Medical imaging
- Robotics
- Biomedical engineering
Background:
- Accurate tracking of interventional tools during ultrasound-guided procedures is vital for patient safety.
- Current ultrasound probe calibration methods rely on passive phantoms and are sensitive to image quality and parameters.
- Existing methods present challenges including dependency on ultrasound image quality and manual user intervention.
Purpose of the Study:
- To introduce a novel active echo (AE) phantom for ultrasound probe calibration.
- To overcome the limitations of passive phantoms in ultrasound calibration.
- To enhance the accuracy and reliability of ultrasound-guided procedures through improved calibration.
Main Methods:
- Development and implementation of an active echo (AE) phantom that actively responds to ultrasound beams.
- Utilizing the AE phantom for automatic identification of the ultrasound image mid-plane.
- Comparing the AE phantom with a gold standard crosswire (CW) phantom in a robotic ultrasound setup.
- Evaluating autosegmentation capabilities of the AE phantom.
Main Results:
- The AE phantom provides a localization precision of 223 μm.
- An overall reconstruction error of 850 μm was achieved with the AE phantom.
- Autosegmentation using the AE phantom demonstrated performance comparable to manual segmentation.
- The AE phantom's performance is independent of ultrasound image quality.
Conclusions:
- The active echo phantom offers a reliable and accurate solution for ultrasound probe calibration.
- This novel phantom minimizes user dependency through automatic localization and segmentation.
- The AE phantom represents a significant advancement for improving safety and outcomes in ultrasound-guided interventions.
More Related Videos
08:19Controllable Nucleation of Cavitation from Plasmonic Gold Nanoparticles for Enhancing High Intensity Focused Ultrasound Applications
Published on: October 5, 2018
06:50Troubleshooting FoCUS Image Acquisition: Patient Positioning, Transducer Manipulation, and Image Optimization
Published on: March 3, 2023
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...