Related Experiment Video
Updated: Apr 19, 2026

Implantation Protocol of the Foldable Capsular Vitreous Body for Complex Vitreoretinal Surgery
Published on: April 14, 2026
Scleral melt following Retisert intravitreal fluocinolone implant
Ilias Georgalas1, Chrysanthi Koutsandrea1, Dimitrios Papaconstantinou1
1Ophthalmology Department, University of Athens, Athens, Greece.
Abstract:
Intravitreal fluocinolone acetonide implant (Retisert) has a high potency, a low solubility, and a very short duration of action in the systemic circulation, enabling the steroid pellet to be small and reducing the risk of systemic side effects. Scleral melt has not been reported as a possible complication of Retisert implant. The authors describe the occurrence of scleral melt 18 months after the implantation of fluocinolone acetonide implant in a 42-year-old Caucasian woman. To the authors' knowledge, this is the first report of this possible complication.
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...