Voltage dependence of Hodgkin-Huxley rate functions for a multistage K^{+} channel voltage sensor within a membrane
1Department of Physics, University of Adelaide, Adelaide, South Australia, 5005, Australia.
Abstract:
The activation of a K^{+} channel sensor in two sequential stages during a voltage clamp may be described as the translocation of a Brownian particle in an energy landscape with two large barriers between states. A solution of the Smoluchowski equation for a square-well approximation to the potential function of the S4 voltage sensor satisfies a master equation and has two frequencies that may be determined from the forward and backward rate functions. When the higher-frequency terms have small amplitude, the solution reduces to the relaxation of a rate equation, where the derived two-state rate functions are dependent on the relative magnitude of the forward rates (α and γ) and the backward rates (β and δ) for each stage. In particular, the voltage dependence of the Hodgkin-Huxley rate functions for a K^{+} channel may be derived by assuming that the rate functions of the first stage are large relative to those of the second stage-α≫γ and β≫δ. For a Shaker IR K^{+} channel, the first forward and backward transitions are rate limiting (α<γ and δ≪β), and for an activation process with either two or three stages, the derived two-state rate functions also have a voltage dependence that is of a similar form to that determined for the squid axon. The potential variation generated by the interaction between a two-stage K^{+} ion channel and a noninactivating Na^{+} ion channel is determined by the master equation for K^{+} channel activation and the ionic current equation when the Na^{+} channel activation time is small, and if β≪δ and α≪γ, the system may exhibit a small amplitude oscillation between spikes, or mixed-mode oscillation, in which the slow closed state modulates the K^{+} ion channel conductance in the membrane.
More Related Videos
Related Concept Videos
Potentiometry: Membrane Electrodes
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Voltage-gated Ion Channels
The Role of Ion Channels in Neuronal Computation
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential....
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Voltammetry: Factors Affecting Measurements