Voltage dependence of Hodgkin-Huxley rate functions for a multistage K^{+} channel voltage sensor within a membrane

S R Vaccaro1

  • 1Department of Physics, University of Adelaide, Adelaide, South Australia, 5005, Australia.

Related Concept Videos

Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
2.4K
Voltage-gated Ion Channels01:26

Voltage-gated Ion Channels

Voltage-gated ion channels are transmembrane proteins that open and close in response to changes in the membrane potential. They are present on the membranes of all electrically excitable cells such as neurons, heart, and muscle cells.
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
13.8K
Voltage-gated Ion Channels01:26

Voltage-gated Ion Channels

7.9K
The Role of Ion Channels in Neuronal Computation01:19

The Role of Ion Channels in Neuronal Computation

A postsynaptic neuron usually receives numerous impulses from several other presynaptic neurons. The axon hillock of the postsynaptic neuron integrates all these signals and determines the likelihood of firing an action potential.
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential....
4.3K
Potentiometry: Types of Electrodes01:19

Potentiometry: Types of Electrodes

Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
2.8K
Voltammetry: Factors Affecting Measurements01:21

Voltammetry: Factors Affecting Measurements

A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
732