Related Experiment Video
Updated: Apr 19, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
11C-Pittsburgh B PET imaging in cardiac amyloidosis
Seung-Pyo Lee1, Eun Seong Lee2, Hongyoon Choi3
1Cardiovascular Center, Seoul National University Hospital, Seoul, Korea; Department of Internal Medicine, Seoul National University College of Medicine, Seoul National University, Seoul, Korea.
Objectives:
This study sought to investigate the efficacy of (11)C-Pittsburgh B (PiB) positron emission tomography (PET)/computed tomography (CT) in the diagnosis of cardiac amyloidosis.
Background:
The PiB compound has been promising for detection of amyloid deposits in the brain.
Methods:
A total of 22 consecutive patients were enrolled in this prospective pilot study of monoclonal gammopathy patients with suspected cardiac amyloidosis. The study consisted of a series of (11)C-PiB PET/CT, echocardiography, cardiac magnetic resonance, and endomyocardial biopsy within a 1-month period. In addition, 10 normal subjects were recruited to determine the most optimal cut-off value for a positive (11)C-PiB PET/CT scan.
Results:
Among the 22 patients, 15 patients were diagnosed as cardiac amyloidosis by endomyocardial biopsy and 5 patients had undergone chemotherapy previously before the (11)C-PiB PET/CT. There were no differences in echocardiographic parameters between patients with versus without cardiac amyloidosis, except for a marginal difference in the left ventricular end-diastolic dimension (median 41.0 mm [range 33.0 to 49.0 mm] vs. 50.0 mm [range 38.0 to 55.0 mm], p = 0.066). (11)C-PiB PET/CT was positive in 13 of 15 biopsy-proven cardiac amyloidosis patients, whereas none of the patients without cardiac amyloidosis demonstrated positive (11)C-PiB PET/CT scan results. The maximal myocardium-to-blood cavity ratio was significantly different between patients with versus without cardiac amyloidosis (median 3.9 [range 1.7 to 19.9] vs. 1.0 [range 0.8 to 1.2], p < 0.001). In association with the significant difference of (11)C-PiB uptake in the myocardium between the chemotherapy naïve versus the previous chemotherapy group (median 10.4 [range 1.7 to 19.9] vs. 2.3 [range 1.7 to 3.8], p = 0.014), all except 1 patient among the 5 previously treated patients had responded to chemotherapy by serum free light chain assay results at the time of (11)C-PiB PET/CT scan.
Conclusions:
(11)C-PiB PET/CT may be valuable for the diagnosis of cardiac amyloidosis noninvasively. Whether (11)C-PiB PET/CT may be a good surrogate marker of active light chain deposition in the myocardium warrants further investigation in a larger number of patients.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies for Cardiovascular System V: CT
![PET Imaging of Neuroinflammation Using [11C]DPA-713 in a Mouse Model of Ischemic Stroke](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F57243.jpg&w=3840&q=50)