Related Experiment Video
Updated: Apr 19, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Dynamic preload markers to predict fluid responsiveness during and after major gastrointestinal surgery: an
N MacDonald1, T Ahmad1, O Mohr2
1Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, UK.
Background:
Stroke volume variation (SVV) and pulse pressure variation (PPV), termed dynamic markers of preload responsiveness, may predict the response to i.v. fluid in critically ill patients. However, the predictive accuracy of these variables during gastrointestinal surgery remains uncertain.
Methods:
Observational study of patients aged ≥50 yr undergoing major gastrointestinal surgery, enrolled in the OPTIMISE trial. Patients received six 250 ml fluid challenges with i.v. colloid solution (three during and three after surgery), while SVV and PPV were measured using the LiDCOrapid monitor (LiDCO Ltd, UK). Fluid responsiveness was defined as a stroke volume increase ≥10%. Area under the receiver operating characteristic curve was calculated with 95% confidence intervals. Adjustment for covariates was performed by regression modelling and a clustering method was used to adjust for intra-patient correlation.
Results:
One hundred patients were recruited between August 2010 and October 2012. Five hundred and fifty-six fluid challenges were administered and 159 (28.6%) were associated with increased stroke volume. The predictive value of both variables was poor during surgery [SVV 0.69 (0.63-0.77); PPV 0.70 (0.62-0.77)], and also after surgery [SVV 0.69 (0.63-0.78); PPV 0.64 (0.56-0.73)]. The findings were similar when analysed according to whether patients were mechanically ventilated [SVV 0.68 (0.63-0.77); PPV 0.69 (0.61-0.77)] or breathing spontaneously [SVV 0.69 (0.61-0.77); PPV 0.63 (0.56-0.72)]. Predictive value improved slightly in a sensitivity analysis excluding outlier values of SVV and PPV.
Conclusions:
In this study, the predictive accuracy of SVV and PPV for fluid responsiveness was insufficient to recommend for routine clinical use during or after major gastrointestinal surgery.
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Aneurysm IV: Nursing Management
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Peripheral Artery Disease V: Postoperative Nursing Management
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Inflammatory Bowel Disease V: Surgical Management
Here are some common surgical interventions for IBD:

