Related Experiment Video
Updated: Apr 19, 2026

Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
Published on: January 7, 2021
Visualization of placental hypocirculation with typical patterns using conventional magnetic resonance imaging: Two
Yuki Himoto1, Aki Kido, Sachiko Minamiguchi
1Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
We report two cases of clinically suspected placental hypocirculation, as per evidenced by specific half-Fourier acquisition single-shot turbo spin-echo (HASTE) magnetic resonance findings of the whole placenta. Patient 1 was a case of fetal growth restriction caused by pregnancy-induced hypertension, while patient 2 experienced a discordant dichorionic diamniotic twin pregnancy with fetal growth restriction complication with a velamentous insertion of the umbilical cord in the smaller twin. In both cases, HASTE images showed noticeably decreased signal intensity with high-intensity signal spots present in the central region of the placenta. In the twin pregnancy case, the low-intensity signal area in the placenta of the smaller twin was much lower compared to that of the larger twin. Pathological findings failed to support or explain these observations. HASTE images might reflect compensatory alternation of the distribution of maternal blood and villus caused by hypocirculation. In conclusion, our results suggest that HASTE imaging might be a useful approach for the visualization of placental hypocirculation.
We report two cases of clinically suspected placental hypocirculation, as per evidenced by specific half-Fourier acquisition single-shot turbo spin-echo (HASTE) magnetic resonance findings of the whole placenta. Patient 1 was a case of fetal growth restriction caused by pregnancy-induced hypertension, while patient 2 experienced a discordant dichorionic diamniotic twin pregnancy with fetal growth restriction complication with a velamentous insertion of the umbilical cord in the smaller twin. In both cases, HASTE images showed noticeably decreased signal intensity with high-intensity signal spots present in the central region of the placenta. In the twin pregnancy case, the low-intensity signal area in the placenta of the smaller twin was much lower compared to that of the larger twin. Pathological findings failed to support or explain these observations. HASTE images might reflect compensatory alternation of the distribution of maternal blood and villus caused by hypocirculation. In conclusion, our results suggest that HASTE imaging might be a useful approach for the visualization of placental hypocirculation.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies VII: Vascular Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...

