Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

3.2K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
3.2K
Peptide Identification Using Tandem Mass Spectrometry01:33

Peptide Identification Using Tandem Mass Spectrometry

8.8K
Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
8.8K
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

2.2K
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
2.2K
MALDI-TOF Mass Spectrometry01:19

MALDI-TOF Mass Spectrometry

7.8K
Mass spectrometry is a powerful characterization technique that can identify and separate a wide variety of compounds ranging from chemical to biological entities, based on their mass-to-charge ratio (m/z). The instruments that allow this detection, known as mass spectrometers, have three components: an ion source, a mass analyzer, and a detector. These spectrometers differ based on the nature of their ion source and analyzers.Matrix-assisted laser desorption ionization (MALDI) is a commonly...
7.8K
Mass Spectrometers01:16

Mass Spectrometers

11.3K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
11.3K
Mass Spectrometry: Overview01:19

Mass Spectrometry: Overview

10.9K
Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electron ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave behind a...
10.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Direct-to-definitive urine drug screening in children unmasks false-negative immunoassay screening.

Clinica chimica acta; international journal of clinical chemistry·2026
Same author

Modern Low-Density Lipoprotein Cholesterol Formulas Outperform Direct Methods in Patients with Hypertriglyceridemia and Low Levels of Low-Density Lipoprotein Cholesterol.

Clinical chemistry·2025
Same author

Fetal Fraction Methodologies and Their Clinical Use: Results of a College of American Pathologists Exercise.

The journal of applied laboratory medicine·2025
Same author

Markedly Elevated Citrulline in a Neonate: Citrin Deficiency due to a Previously Unreported Solute Carrier Family 25 Member 13 Variant.

Clinica chimica acta; international journal of clinical chemistry·2025
Same author

Elevated C5-hydroxy acylcarnitine in an infant girl as a result of holocarboxylase synthetase deficiency.

Clinica chimica acta; international journal of clinical chemistry·2024
Same author

Numbers of prenatal cell-free DNA screens performed: Results of a 2022 CAP exercise.

Prenatal diagnosis·2024
Same journal

Extremely high follicle-stimulating hormone with normal ovarian function.

Clinical biochemistry·2026
Same journal

Analytical outlier rates for Roche fifth generation cardiac troponin T stat using biotin sensitive and insensitive reagent lots.

Clinical biochemistry·2026
Same journal

Evaluation of hemoglobin interference thresholds for chemical urinalysis panels.

Clinical biochemistry·2026
Same journal

Integrated genomic and biochemical diagnosis of a novel homozygous start-loss variant in AKR1D1 associated with neonatal cholestasis.

Clinical biochemistry·2026
Same journal

Agreement between POC glucose meters and blood gas analyzers varies across ICU patient populations.

Clinical biochemistry·2026
Same journal

From variability to value: Advancing vancomycin therapeutic drug monitoring toward decision-grade practice through commutability-informed external quality assessment and uncertainty-aware reporting.

Clinical biochemistry·2026
See all related articles

Related Experiment Video

Updated: Apr 19, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
08:40

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments

Published on: January 20, 2022

5.0K

Tandem MS: it's now the norm

Patricia M Jones1, Nathalie Lepage2

  • 1Chemistry and Metabolic Disease Laboratory, Children's Medical Center Dallas, USA; Department of Pathology, UT Southwestern Medical Center, USA.

Clinical Biochemistry
|December 17, 2014
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
10:37

Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification

Published on: November 15, 2017

12.9K
Analyzing Large Protein Complexes by Structural Mass Spectrometry
15:35

Analyzing Large Protein Complexes by Structural Mass Spectrometry

Published on: June 19, 2010

25.0K

Related Experiment Videos

Last Updated: Apr 19, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
08:40

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments

Published on: January 20, 2022

5.0K
Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
10:37

Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification

Published on: November 15, 2017

12.9K
Analyzing Large Protein Complexes by Structural Mass Spectrometry
15:35

Analyzing Large Protein Complexes by Structural Mass Spectrometry

Published on: June 19, 2010

25.0K