Related Experiment Video
Updated: Jul 2, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Agreement between POC glucose meters and blood gas analyzers varies across ICU patient populations
1Department of Pathology and Molecular Medicine, Queen's University, 76 Stuart Street, Kingston, ON K7L 2V7, Canada.
Background:
Point-of-care (POC) glucose meters are widely used in intensive care units (ICUs) for rapid glucose monitoring. However, their accuracy may be affected by pathological and physiological factors in different critically ill patients.
Methods:
Dataset 1 consisted of a three-year quality assurance (QA) practice (2022-2024) using non-ICU samples. Dataset 2 included paired glucose results from patients in general ICU, cardiac ICU, and neonatal ICU collected over six months (July to December 2024), with measurements obtained within a 20-min interval. Agreement of results between glucose meters and blood gas analyzers (BGAs) was assessed using Deming regression, ISO 15197:2013 criteria, and the Diabetes Technology Society (DTS) Error Grid.
Results:
In the QA dataset (n = 1476), glucose meter results showed excellent correlation with BGAs (r = 0.9930), with 92.6% (<5.0 mmol/L) and 88.2% (≥5.0 mmol/L) of results meeting ISO criteria. In ICU patients (n = 985), correlation was significantly lower (r = 0.8509), with slightly reduced agreement at higher glucose concentrations (82.5%). Performance varied across ICU populations, with the lowest correlation observed in the general ICU (r = 0.8068). Agreement at critically high glucose levels was markedly reduced in clinical settings compared with QA data (43.2% vs. 74.2%). DTS Error Grid analysis showed that 1.23% of the differences between glucose meters and BGAs fell within moderate- or high-risk zones.
Conclusions:
The analytical accuracy of POC glucose meters is significantly reduced in ICU settings and varies among patient populations. Meter performance evaluation should be conducted under real clinical conditions, with particular attention to extreme glucose levels. The performance data should be shared with ICU physicians to support appropriate interpretation of glucose results.
Related Concept Videos
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...