Related Experiment Video
Updated: Apr 19, 2026

Author Spotlight: Advancing Lung Disease Research with Free-Breathing Hyperpolarized Xenon-129 MRI
Published on: November 10, 2023
Uncertainty induced by chest wall thickness assessment methods on lung activity estimation for plutonium and
D Broggio1, X Lechaftois, D Franck
1Institut de Radioprotection et de Sûreté Nucléaire, IRSN/PRP-HOM/SDI/LEDI, 92262 Fontenay-aux-Roses Cedex, France.
Abstract:
In vivo lung counting aims at assessing the retained activity in the lungs. The calibration factor relating the measured counts to the worker's specific retained lung activity can be obtained by several means and strongly depends on the chest wall thickness. Here we compare, for 374 male nuclear workers, the activity assessed with a reference protocol, where the material equivalent chest wall thickness is known from ultrasound measurements, with two other protocols. The counting system is an array of four germanium detectors.It is found that non site-specific equations for the assessment of the chest wall thickness induce large biases in the assessment of activity. For plutonium isotopes or (241)Am the proportion of workers for whom the retained activity is within ± 10% of the reference one is smaller than 10%.The use of site-specific equations raises this proportion to 20% and 58% for plutonium and (241)Am, respectively.Finally, for the studied population, when site-specific equations are used for the chest wall thickness, the standard uncertainties for the lung activity are 42% and 12.5%, for plutonium and (241)Am, respectively. Due to the relatively large size of the studied population, these values are a relatively robust estimate of the uncertainties due to the assessment of the chest wall thickness for the current practice at this site.
More Related Videos
12:22Speciation and Bioavailability Measurements of Environmental Plutonium Using Diffusion in Thin Films
Published on: November 9, 2015
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Propagation of Uncertainty from Systematic Error
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Pneumothorax-II
Clinical Manifestations: