Atmospheric-pressure Molecular Imaging of Biological Tissues and Biofilms by LAESI Mass Spectrometry
Published on: September 3, 2010
Plasma ionization source for atmospheric pressure mass spectrometry imaging using near-field optical laser ablation
Maryia M Nudnova1, Jérôme Sigg, Pascal Wallimann
1Department of Chemistry and Applied Biosciences, ETH Zurich , CH-8093 Zurich, Switzerland.
Abstract:
Mass spectrometry imaging (MSI) at ambient pressures with submicrometer resolution is challenging, due to the very low amount of material available for mass spectrometric analysis. In this work, we present the development and characterization of a method for MSI based on pulsed laser ablation via a scanning near-field optical microscopy (SNOM) aperture tip. SNOM allows laser ablation of material from surfaces with submicrometer spatial resolution, which can be ionized for further chemical analysis with MS. Efficient ionization is realized here with a custom-built capillary plasma ionization source. We show the applicability of this setup for mass spectrometric analysis of three common MALDI matrices, α-4-hydroxycyanocinnamic acid, 3-aminobenzoic acid, and 2,5-dihydroxybenzoic acid. Although the ultimate goal has been to optimize sensitivity for detecting material ablated from submicrometer diameter craters, the effective lateral resolution is currently limited by the sensitivity of the MS detection system. In our case, the sensitivity of the MS was about 1 fmol, which allowed us to achieve a spatial resolution of 2 μm. We also characterize the analytical figures of merit of our method. In particular, we demonstrate good reproducibility, a repetition rate in the range of only a few seconds, and we determined the amount of substance required to achieve optimal resolution and sensitivity. Moreover, the sample topography is available from SNOM scans, a parameter that is missing in common MSI methods.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation
Matrix-Assisted Laser Desorption Ionization (MALDI)
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....