Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
New monitoring techniques to diagnose the cause of syncope
1Arrhythmia Institute of the Valley Hospital Health System, Ridgewood, NJ and New York, NY, United States. mittsu@valleyhealth.com.
Abstract:
Syncope is a very common clinical problem. Given the extensive differential diagnosis, we have developed a structured approach for the evaluation and management of patients with unexplained syncope. Patients with overt cardiac, neurologic, or metabolic disturbances are identified and treated accordingly. However, the remaining patients with high-risk characteristics are hospitalized for risk stratification. After excluding patients who can benefit from pacemaker or implantable cardioverter-defibrillator implantation, an implantable loop recorder (ILR) appears to be a very effective diagnostic tool. The recent availability of a small ILR that can be implanted within minutes and provides daily data wirelessly for over 3 years appears to have elevated the ILR over short-term external electrocardiography (ECG) monitoring techniques in patients with unexplained syncope. Herein, using specific case examples, we review how we use a structural pathway at our institution to guide the evaluation and management of patients presenting with unexplained syncope, identify the types of patients who benefit from long-term ECG monitoring, and show how this strategy has positively affected clinical care in these patients.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
07:12Real-Time Monitoring of Neurocritical Patients with Diffuse Optical Spectroscopies
Published on: November 19, 2020
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Dysrhythmias V: Evaluating Dysrhythmias
Holter Monitor: 24-Hour Monitoring
Dysrhythmias VII: Nursing Management of Dysrhythmias
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.