Related Experiment Video
Updated: Apr 19, 2026

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Validation of the SenseWear Armband in different ambient temperatures
Karen Van Hoye1, Filip Boen, Johan Lefevre
1a Physical Activity, Sports and Health, Kinesiology , Leuven , Belgium.
Abstract:
This study examines the validity of the SenseWear Armband in different temperatures using the old (SenseWear v2.2) and newest version of the algorithm (SenseWear v5.2) against indirect calorimetry (IC). Thirty-nine male and female students (21.1 ± 1.41 years) completed an exercise trial in 19°C, 26°C and 33°C consisting of 5 min standing followed by alternating walking/running at 35% and 65% of their maximal oxygen uptake. The accuracy of the algorithms was evaluated by comparing estimated energy expenditure (EE) to IC using a mixed-model design. No difference was reported in EE between the different temperatures for IC. Both algorithms estimated EE significantly higher when exercising at high intensity in 33°C compared to 19°C. Compared to IC, SenseWear v2.2 accurately estimated EE during standing and light intensity exercise but underestimated EE when exercising in a hot environment and at high intensity. SenseWear v5.2 showed a difference when exercising at high intensity in thermoneutral and warm conditions. The new algorithm improved EE estimation in hot environments and at high intensity compared to the old version. However, given the inherent inaccuracy of the EE estimates of SenseWear, greater weight should be given to direct monitor outputs rather than the ability of a monitor to estimate EE precisely.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Thermosensation
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...