Nitinol flexigrip sternal closure system and standard sternal steel wiring: insight from a matched comparative
Jonida Bejko1, Tomaso Bottio, Vincenzo Tarzia
1Department of Cardiac Surgery, University of Padua, Medical School of Padua, Italy.
Objective:
We sought to assess the efficiency of two different sternal closure techniques in preventing sternal wound instability in high-risk patients.
Materials And Methods:
Between January 2009 and February 2012, 2068 consecutive cardiac patients were prospectively collected in our database. The 561 patients in whom the thermoreactive nitilium clips (Flexigrip) have been used (group A) were matched 1 : 1 with 561 patients who received a standard parasternal wiring technique (group B) on 10 available risk factors known to affect sternal wound healing (age, age >75 years, sex, diabetes mellitus, cardiac procedure, obesity, re-intervention, cross-clamp, and total operative times). The study was completed with a cost analysis.
Results:
The two groups were well matched, although different for bilateral internal thoracic harvesting, chronic obstructive pulmonary disease, renal insufficiency, and congestive heart failure, which were significantly more frequent in group A. At 30 days of follow-up, the association of wound complication and sternal instability was significantly less frequent in group A versus group B (0.2 versus 1.6%) (P = 0.04). Overall incidence of sternal wound complication was lower in group A (2 versus 3.5%) (P = 0.28). In the presence of wound infection, a sternal wound instability was never observed in group A (P = 0.06). Overall costs were €8,701,854 and €9,243,702 in groups A and B, respectively; thus the Flexigrip closure technique offered a €541,848 cost saving.
Conclusions:
Flexigrip use in high-risk patients showed a lower incidence of sternal wound instability with no need for sternal re-wiring in any case, even in the presence of wound infection.
More Related Videos
Related Concept Videos
Steel Fastening Techniques
Rivets are cylindrical steel fasteners with a specially designed head. During application, rivets are heated until white-hot and then inserted through pre-drilled holes in the steel sections. A pneumatic hammer is used to shape the exposed end into a second head, securing the sections together.
Bolting is another...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...