Image Acquisition Method for the Sonographic Assessment of the Inferior Vena Cava
Published on: January 13, 2023
Effect of postural changes on inferior vena cava dimensions and its influence on haemodynamics during caesarean
P Kundra1, G Arunsekar1, A Vasudevan1
1a Department of Anaesthesiology & Critical Care , JIPMER , Puducherry , India.
The effect of postural changes on inferior vena cava (IVC) dimensions and its influence on intra-operative haemodynamics in term parturients can be studied using abdominal ultrasound by a subcostal approach. Thirty-two term parturients scheduled to undergo elective caesarean section under spinal anaesthesia were recruited in this observational study. End expiratory diameter and collapsibility index of IVC was measured preoperatively in 3 different positions - supine, recumbent with wedge and left lateral positions. End expiratory diameter was significantly high in recumbent (10.79) and left lateral (12.27) compared with supine (9.96) position (P < 0.0001). A greater fall in systolic blood pressure (>20%) was noted in patients with collapsibility index of more than 11.5 in recumbent with wedge position with a positive predictive value of 86%. IVC dimensions change significantly with change in position and collapsibility index in recumbent position can be a useful parameter for predicting hypotension during caesarean section under spinal anaesthesia.
The effect of postural changes on inferior vena cava (IVC) dimensions and its influence on intra-operative haemodynamics in term parturients can be studied using abdominal ultrasound by a subcostal approach. Thirty-two term parturients scheduled to undergo elective caesarean section under spinal anaesthesia were recruited in this observational study. End expiratory diameter and collapsibility index of IVC was measured preoperatively in 3 different positions - supine, recumbent with wedge and left lateral positions. End expiratory diameter was significantly high in recumbent (10.79) and left lateral (12.27) compared with supine (9.96) position (P < 0.0001). A greater fall in systolic blood pressure (>20%) was noted in patients with collapsibility index of more than 11.5 in recumbent with wedge position with a positive predictive value of 86%. IVC dimensions change significantly with change in position and collapsibility index in recumbent position can be a useful parameter for predicting hypotension during caesarean section under spinal anaesthesia.
More Related Videos
03:14Author Spotlight: Enhancing Success of Ultrasound-Guided Neuraxial Anesthesia in Cases with Difficult Anatomy
Published on: January 31, 2025
04:33Spinal Hernia Repair and Cauda Equina Repositioning After Lumbar Decompression under Three-Dimensional Microscopy: A Case Report and Literature Review
Published on: November 8, 2024
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Aneurysm IV: Nursing Management
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Local Anesthetics: Clinical Application as Spinal Anesthesia
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Cardiac Catheterization IV: Nursing Management