Evaluation of the Metabolic Activity of Echinococcus multilocularis in Rodents Using Positron Emission Tomography
Anna-Maria Rolle1, Peter T Soboslay, Gerald Reischl
1Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University, Röntgenweg 13, 72076, Tübingen, Germany.
Purpose:
2-Deoxy-2-[(18)F]fluoro-D-glucose ([(18)F]FDG) has been used as a standard clinical positron emission tomography (PET) tracer for the follow-up of the rare but life-threatening parasitic disease alveolar echinococcosis (AE). Given that the disease is endemic in many countries in the northern hemisphere and the diagnosis is still challenging, the aim of our study was to evaluate further clinically relevant PET tracers as possible diagnostic tools for AE in vitro and in vivo.
Procedures:
Various clinically used PET tracers were evaluated in vitro and assessed in an in vivo AE animal model based on PET/magnetic resonance (MR) measurements.
Results:
In vitro binding assays displayed high uptake of [(18)F]FDG in a cell suspension of E. multilocularis tissue, whereas 3'-deoxy-3'-[(18)F]fluorothymidine ([(18)F]FLT) and [(11)C]choline were found to be taken up strongly by E. multilocularis vesicles. [(18)F]FDG and [(18)F]FLT displayed an elevated uptake in vivo, which appeared as several foci throughout the parasite tissue as opposed to [(18)F]fluoro-azomycinarabinofuranoside ([(18)F]FAZA) and [(11)C]choline.
Conclusions:
Our data clearly demonstrate that the clinically applied PET tracer [(18)F]FDG is useful for the diagnosis and disease staging of AE but also has drawbacks in the assessment of currently inactive or metabolically weak parasitic lesions. The different tested PET tracers do not show the potential for the replacement or supplementation of current diagnostic strategies. Hence, there is still the need for novel diagnostic tools.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
10:04Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
