Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Enhancing the pulse contour analysis-based arterial stiffness estimation using a novel photoplethysmographic
Abstract:
In this paper, we propose a novel method for enhancing pulse contour analysis-based arterial stiffness estimation using a simple and low-complexity photoplethysmographic parameter (P2Ocd). The method first eliminates baseline wanders in the digital volume pulse (DVP) by applying a simple morphological filter. The filtered DVP signal is then transformed into a slope sum function signal to simplify the pulse peak detection process by enhancing the upslope of the DVP signal while suppressing its downslope. An adaptive thresholding scheme is applied to detect pulse peaks from the transformed signal. Pulse onsets are then identified as the minimum values between consecutive pulse peaks. The P2Ocd is finally calculated by dividing the time interval between the pulse peak and the pulse onset by the pulse length. In order to assess the agreement of the P2Ocd with an established technique, brachial-ankle pulse wave velocity, we performed Bland-Altman and correlation analyses. Furthermore, we evaluated the P2Ocd-based arterial stiffness estimation in terms of prediction accuracy (% error rate) and repeatability (coefficient of variation). The results show that the proposed measurement agrees well with the established technique and shows a high repeatability; it also has a better predictive accuracy than that of conventional methods. In addition, we show that the proposed parameter further improves the predictive accuracy by combining it with age. The proposed method is therefore highly applicable to small ubiquitous healthcare applications.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: