Related Experiment Video
Updated: Apr 18, 2026

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Macroscopic barotrauma caused by stiff and soft-tipped airway exchange catheters: an in vitro case series
Robert Axe1, Alex Middleditch, Fiona E Kelly
1From the *Department of Anaesthesia and Intensive Care Medicine, Royal United Hospital Bath, Bath, United Kingdom; and †Department of Thoracic Surgery, Bristol Royal Infirmary, Bristol, United Kingdom.
Background:
Many airway management guidelines include the use of airway exchange catheters (AECs). There are reports, however, of harm from their use, from both malpositioning and in particular from the administration of oxygen via an AEC leading to barotrauma.
Methods:
We used an in vitro pig lung model to investigate the safety of administering oxygen at 4 different flow rates from a high-pressure source via 2 different AECs: a standard catheter and a soft-tipped catheter. Experiments were performed with the catheters positioned either above the carina or below it at the first point of resistance to advancement (hold-up). The experiments were then repeated to produce a series of 32 cases.
Results:
With an AEC positioned above the carina, we did not observe macroscopic lung damage after the administration of oxygen. The administration of oxygen through an AEC positioned below the carina resulted in macroscopic barotrauma regardless of the rate of oxygen delivery. Increasing speed of oxygen flow led to faster and more extensive damage. Use of an "injector" at 2.5 or 4 bar led to instantaneous macroscopic lung damage and advancement of the AEC through the lung tissue. Our observations were the same when both types of AECs were used.
Conclusions:
Our results are consistent with reports of harm during the use of AECs and demonstrate the risk of administering oxygen through these devices when they are positioned below the carina. An indicator, ideally made on an AEC at the time of manufacture and designed to lie at the same level as the teeth, may be useful in preventing the insertion of that AEC beyond the level of the carina and improve the safety of using such devices.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Suctioning the Nasopharyngeal Airway
Equipment Required
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Tracheostomy Suctioning II: Procedure