Effect of clot formation and retraction on spin-echo MR images of blood: an in vitro study
Abstract:
Phantoms were constructed that contained red blood cell (RBC)-free clots in varying stages of clot retraction. MR images of these samples were compared with those of retracted whole venous blood clots and a fresh rat brain standard. Images were obtained at 0.3 T, 0.5 T, 1.0 T, 1.5 T, and 2.4 T with T1-, spin-density- and T2-weighted spin-echo pulse sequences. The presence or absence of venous blood cells in the clot caused only minor differences in T2- and spin-density-weighted images of the clots at or below 1.5 T. On T2-weighted scans, the retraction of the RBC-free clot resulted in a progressive decrease in signal intensity at 2.4 T. Fully retracted RBC-free clots were markedly hypointense relative to serum and ranged from slightly hyperintense to isointense with brain and venous clots at 0.5-1.5 T. There were no striking concomitant signal intensity changes on the spin-density- or T1-weighted scans, which could have caused the changes seen on the T2-weighted images of the clots. Our results indicate that the physical basis of these MR effects in the RBC-free clots is the concentration of plasma protein. The combined concentration of plasma protein and the tightly packed RBC proteins in the venous clots causes the strikingly similar MR appearance of venous and RBC-free clots on clinical images. These results do not demonstrate the presence of the previously postulated selective T2 relaxation of intracellular paramagnetic deoxyhemoglobin in these in vitro venous clots.
Insights
Magnetic resonance imaging (MRI) of red blood cell (RBC)-free clots shows signal intensity changes due to plasma protein concentration. These findings explain the similar MR appearance of venous and RBC-free clots.
Area of Science:
- Biophysics
- Medical Imaging
Background:
- Understanding the magnetic resonance (MR) signal characteristics of blood clots is crucial for accurate diagnosis.
- Previous studies postulated selective T2 relaxation of deoxyhemoglobin in venous clots.
Purpose of the Study:
- To investigate the MR imaging appearance of red blood cell (RBC)-free clots at various retraction stages.
- To determine the physical basis of MR signal changes in these clots and compare them to whole venous clots.
Main Methods:
- Phantoms with RBC-free clots and whole venous clots were imaged at field strengths from 0.3 T to 2.4 T.
- T1-, spin-density-, and T2-weighted spin-echo pulse sequences were utilized.
- Images were compared with a fresh rat brain standard.
Main Results:
- RBC-free clots showed minor differences on T2- and spin-density-weighted images below 1.5 T.
- At 2.4 T, retracted RBC-free clots exhibited progressive signal intensity decrease on T2-weighted scans.
- Signal intensity changes were attributed to plasma protein concentration, not deoxyhemoglobin relaxation.
Conclusions:
- Plasma protein concentration is the primary driver of MR signal changes in RBC-free clots.
- The combined effect of plasma and RBC proteins explains the similar MR appearance of venous and RBC-free clots.
- Selective T2 relaxation of deoxyhemoglobin was not demonstrated in these in vitro venous clots.
More Related Videos
13:10Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
09:19In Vitro Microfluidic Disease Model to Study Whole Blood-Endothelial Interactions and Blood Clot Dynamics in Real-Time
Published on: May 24, 2020
Related Concept Videos
Magnetic Resonance Imaging
Clot Retraction and Fibrinolysis