Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
PET(CO2) measurement and feature extraction of capnogram signals for extubation outcomes from mechanical ventilation
Carmen C Rasera1, Pedro M Gewehr, Adriana Maria T Domingues
1Graduate Program in Electrical and Computer Engineering, Biomedical Engineering, Federal University of Technology-Parana (UTFPR), Brazil.
Abstract:
Capnography is a continuous and noninvasive method for carbon dioxide (CO2) measurement, and it has become the standard of care for basic respiratory monitoring for intubated patients in the intensive care unit. In addition, it has been used to adjust ventilatory parameters during mechanical ventilation (MV). However, a substantial debate remains as to whether capnography is useful during the process of weaning and extubation from MV during the postoperative period. Thus, the main objective of this study was to present a new use for time-based capnography data by measuring the end-tidal CO2 pressure ([Formula: see text]), partial pressure of arterial CO2 ([Formula: see text]) and feature extraction of capnogram signals before extubation from MV to evaluate the capnography as a predictor of outcome extubation in infants after cardiac surgery. Altogether, 82 measurements were analysed, 71.9% patients were successfully extubated, and 28.1% met the criteria for extubation failure within 48 h. The ROC-AUC analysis for quantitative measure of the capnogram showed significant differences (p < 0.001) for: expiratory time (0.873), slope of phase III (0.866), slope ratio (0.923) and ascending angle (0.897). In addition, the analysis of [Formula: see text] (0.895) and [Formula: see text] (0.924) obtained 30 min before extubation showed significant differences between groups. The [Formula: see text] mean value for success and failure extubation group was 39.04 mmHg and 46.27 mmHg, respectively. It was also observed that high CO2 values in patients who had returned MV was 82.8 ± 21 mmHg at the time of extubation failure. Thus, [Formula: see text] measurements and analysis of features extracted from a capnogram can differentiate extubation outcomes in infant patients under MV, thereby reducing the physiologic instability caused by failure in this process.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Mechanical Ventilation I: Indication and Settings
Acute Respiratory Failure-III
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...