Related Experiment Video
Updated: Apr 18, 2026

05:25
Author Spotlight: Developing Efficient Cryopreservation and Biobanking Technologies for Global Reef Restoration
Published on: June 7, 2024
1.5K
Optimizing human semen cryopreservation by reducing test vial volume and repetitive test vial sampling
Christian F S Jensen1, Dana A Ohl2, Walter R Parker2
1Department of Urology, University of Michigan, Ann Arbor, Michigan; Department of Urology, Herlev University Hospital, Herlev, Denmark; Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
Fertility and Sterility
|January 15, 2015
Summary
A 100 μL test vial (TV) is optimal for predicting human semen cryosurvival (CS). Long-term storage in nitrogen vapor (VN2) is stable and safe, ensuring reliable cryopreservation outcomes.
Area of Science:
- Reproductive Medicine
- Cryobiology
- Andrology
Background:
- Optimizing semen cryopreservation is crucial for assisted reproductive technologies (ART).
- Standardization of test vial (TV) volumes and storage conditions is needed for reliable cryosurvival (CS) prediction.
Purpose of the Study:
- To determine the optimal test vial (TV) volume for human semen cryopreservation.
- To evaluate the reliability of TVs for predicting cryosurvival (CS).
- To assess the impact of intermediate temperature exposure and long-term storage in nitrogen vapor (VN2) versus liquid nitrogen (LN2) on semen viability.
Main Methods:
- A prospective clinical laboratory study involving 594 patients undergoing semen analysis and cryopreservation.
- Evaluation of various test vial (TV) volumes (50-1,000 μL) and cryostorage conditions, including intermediate temperatures (-88°C to -93°C) and storage in VN2 and LN2.
- Analysis of post-thaw motility and cryosurvival (CS) rates.
Main Results:
- A 50 μL TV volume resulted in lower cryosurvival (CS) compared to larger volumes; 100 μL TVs showed similar CS to larger volumes.
- Intermediate temperature exposure did not negatively impact post-thaw motility.
- Cryosurvival (CS) in test vials (TVs) and ART procedure vials (ARTVs) from the same ejaculate were comparable, with strong correlation between the first TV and subsequent ARTVs.
- Long-term cryostorage in nitrogen vapor (VN2) did not affect cryosurvival (CS).
Conclusions:
- A single 100 μL TV per patient is sufficient to predict cryosurvival (CS) when freezing multiple ejaculates within a short timeframe (<10 days).
- Semen cryostorage in nitrogen vapor (VN2) offers a stable and safe long-term preservation environment.