Related Experiment Video
Updated: Apr 18, 2026

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Characteristics and trends of POBA in current DES Era
Manabu Moriya1, Sugao Ishiwata2, Yo Fujimoto2
1Department of Cardiology, Cardiovascular Center, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan. mmoriya@toranomon.gr.jp.
Abstract:
The aim of this study is to clarify the characteristics and trends of POBA in current drug-eluting stent (DES) era. We examined retrospectively the cases of POBA performed in our institute during the years from 2008 to 2012. For control, bare metal stents (BMS) and DES implantation done in 2011 were analyzed. During the period, 85 cases of POBA, 63 BMS and 132 DES were identified. In the result, the rate of restenosis in POBA was significantly higher than BMS and DES (39.7, 14.9, 3.7%, POBA, BMS, DES, respectively, p < 0.001). We assumed three categories depending on the reasons for selecting POBA. (1) Stent delivery failure or expected difficulty of stent delivery due to calcification, etc. (n = 14), (2) intervention for in-stent restenosis or stent thrombosis (n = 34), (3) successful POBA applied to small vessels without complication (n = 14). According to it, category 1 showed significantly high probability of restenosis compared with others [(1) 10/14, 71.4%, (2) 12/34, 35.3%, 3; 2/14, 14.3%, p < 0.05]. In addition, category 3 showed nearly as good as BMS. Balloons used in POBA contained 32 non-compliant balloons and 14 scoring balloons, whereas 30 were semi-compliant balloons only. ACC/AHA lesion type B2/C was 85.7, 45.7 and 50.0%, and cases treated only with semi-compliant balloon were 57.1, 14.3, 92.9% (category (1), (2) and (3), respectively, both p < 0.05). Therefore, this fact shows that a case of small vessel of which diameter is less than 2.5 mm would have a favorable outcome with POBA when treated well only with semi-compliant balloon under the current DES era.
More Related Videos
06:55Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents
Published on: October 26, 2016
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Peripheral Artery Disease III: Interprofessional Care
Coronary Artery Disease V: Interprofessional Care
Antiplatelet Drugs: Prostaglandin Synthesis, P2Y12 and Glycoprotein IIb/IIIa Inhibitors
Prostaglandin synthesis inhibitors, exemplified by the widely known aspirin, wield their power by irreversibly acetylating...
Angina IV: Management
Atherosclerosis III: Management