Related Experiment Video
Updated: Apr 18, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Echo Doppler Estimation of Pulmonary Capillary Wedge Pressure in Patients with Severe Aortic Stenosis
Simon Biner1, Yan Topilsky1, Shmuel Banai1
1Department of Cardiology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
Background:
Transcatheter aortic valve replacement (TAVR) has become a treatment option for patients with severe aortic stenosis (AS) and high surgical risk. Assessment of symptoms in these patients is challenging because of advanced age, comorbidities, and limited physical activity. Noninvasive quantification of pulmonary capillary wedge pressure (PCWP) in candidates for TAVR may be helpful for risk stratification. The objective of the study was to create a model for estimation of PCWP by echo Doppler in patients with severe AS.
Methods And Results:
Data from 80 patients with severe AS referred for TAVR were used to develop an echo Doppler model for predicting PCWP. Its performance was evaluated in the test cohort of 33 patients who had invasive and noninvasive evaluation. No single echo Doppler parameter estimated PCWP accurately. In the retrospective analysis, the multilinear regression provided an accurate estimate of PCWP (r(2) = 0.74). The model included, in order of importance (all P < 0.05), the ratio of early transmitral velocity (E) to annular velocity (E'), the left ventricular ejection fraction, and the velocity time integral of tricuspid regurgitation signal. In the prospective cohort of patients with severe AS, the model demonstrated good predictive ability of PCWP (r = 0.77, P < 0.01).
Conclusion:
In patients with severe AS, noninvasive estimation of PCWP is possible by integration of two-dimensional, spectral, and tissue Doppler variables.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Aortic Regurgitation IV: Nursing Management