Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

MOSFET Amplifiers01:17

MOSFET Amplifiers

731
The MOSFET, when operating in its active region, functions as a voltage-controlled current source. In this region, the gate-to-source voltage controls the drain current. This principle underlies the operation of the transconductance MOSFET amplifier. The output current is directed through a load resistor to convert this amplifier into a voltage amplifier. The output voltage is then obtained by subtracting the voltage drop across the load resistance from the supply voltage. This process results...
731
Instrumentation Amplifier01:25

Instrumentation Amplifier

1.3K
An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
1.3K
Small-Signal Analysis of MOSFET Amplifiers01:23

Small-Signal Analysis of MOSFET Amplifiers

1.3K
In small-signal analysis, a MOSFET transistor amplifier acts as a linear amplifier when operating in its saturation region. The gate-to-source voltage (VGS) of the MOSFET is the sum of the DC biasing voltage and the small time-varying input signal. This combination sets up the operating point and modulates the drain current (ID) that flows from the drain to the source. When a small AC signal is superimposed on the DC bias voltage at the gate, the instantaneous drain current comprises three...
1.3K
Frequency Response of BJT01:24

Frequency Response of BJT

1.6K
The frequency response of a Bipolar Junction Transistor (BJT) in a common-emitter configuration is critical to its functionality, especially in applications involving amplification of alternating current (AC) signals. This response can be analyzed through low-frequency and high-frequency equivalent circuits, considering various internal parameters and external conditions.
Low-Frequency Response: At low frequencies, the behavior of the BJT is determined by its DC bias point, which is set by the...
1.6K
Cascaded Op Amps01:16

Cascaded Op Amps

1.3K
Operational amplifiers (op-amps) are versatile electronic components that can be interconnected in a cascade - one after another in a linear sequence. This cascading is possible due to their infinite input resistance and zero output resistance, allowing them to maintain their input-output relationships even when connected in series.
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
1.3K
Load-frequency control01:28

Load-frequency control

828
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
828

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Vein of Galen Malformation Masquerading as Neonatal Respiratory Distress.

Cureus·2026
Same author

Chemotaxonomy compared to morphological and anatomical taxonomy of five Hibiscus species.

Journal of plant research·2024
Same author

Assessing the Premedication Properties of Sublingual Melatonin in Young Women Undergoing Cesarean Section With Spinal Anesthesia: A Double-Blind Randomized Study.

Cureus·2024
Same author

Anxiolytic and Sedative Properties of Melatonin Premedication in Pediatrics Undergoing Elective Cardiac Catheterization: A Randomized Placebo Study.

Cureus·2024
Same author

Cytokine expression, protection and shedding reduction induced by the combination of lipopolysaccharide with Montanoid ISA71 in oil-based Newcastle disease vaccine.

Microbial pathogenesis·2024
Same author

Development of multiplex gold nanoparticles biosensors for ultrasensitive detection and genotyping of equine herpes viruses.

Scientific reports·2023
Same journal

RETRACTED: Zhang et al. A Novel Framework for Reconstruction and Imaging of Target Scattering Centers via Wide-Angle Incidence in Radar Networks. <i>Sensors</i> 2025, <i>25</i>, 6802.

Sensors (Basel, Switzerland)·2026
Same journal

Enhancing Unsupervised Multi-Source Domain Adaptation for Person Re-Identification via Mixture of Experts and Graph-Based Relation.

Sensors (Basel, Switzerland)·2026
Same journal

Development of an Instrumented Glove for Palmar Pressure Assessment in Kayakers.

Sensors (Basel, Switzerland)·2026
Same journal

Development and Experimental Validation of an Autonomous IoT-Based Monitoring System for Real-Time Water Quality Assessment in the Amazon River.

Sensors (Basel, Switzerland)·2026
Same journal

Semi-Supervised Adversarial Learning Framework for Controller Area Network Bus Intrusion Detection.

Sensors (Basel, Switzerland)·2026
Same journal

Smart Optimization Method for Safety Signs in Innovative Manufacturing Environments Integrating Industrial Field IoT Sensors and Knowledge Graphs.

Sensors (Basel, Switzerland)·2026
See all related articles

Related Experiment Video

Updated: Apr 18, 2026

A Procedure for Implanting Organized Arrays of Microwires for Single-unit Recordings in Awake, Behaving Animals
10:58

A Procedure for Implanting Organized Arrays of Microwires for Single-unit Recordings in Awake, Behaving Animals

Published on: February 14, 2014

13.8K

Automatic frequency controller for power amplifiers used in bio-implanted applications: issues and challenges.

Mahammad A Hannan1, Hussein A Hussein2, Saad Mutashar3

  • 1Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi Selangor, Malaysia. hannan@eng.ukm.my.

Sensors (Basel, Switzerland)
|January 24, 2015
PubMed
Summary
This summary is machine-generated.

This review surveys power amplifier controllers for bio-implantable devices, finding current automatic frequency controller technologies perform adequately but require further development for optimal efficiency and data rates in wireless medical implants.

More Related Videos

Generation and Coherent Control of Pulsed Quantum Frequency Combs
06:42

Generation and Coherent Control of Pulsed Quantum Frequency Combs

Published on: June 8, 2018

9.8K
The Fabrication and Operation of a Continuous Flow, Micro-Electroporation System with Permeabilization Detection
10:34

The Fabrication and Operation of a Continuous Flow, Micro-Electroporation System with Permeabilization Detection

Published on: January 7, 2022

3.5K

Related Experiment Videos

Last Updated: Apr 18, 2026

A Procedure for Implanting Organized Arrays of Microwires for Single-unit Recordings in Awake, Behaving Animals
10:58

A Procedure for Implanting Organized Arrays of Microwires for Single-unit Recordings in Awake, Behaving Animals

Published on: February 14, 2014

13.8K
Generation and Coherent Control of Pulsed Quantum Frequency Combs
06:42

Generation and Coherent Control of Pulsed Quantum Frequency Combs

Published on: June 8, 2018

9.8K
The Fabrication and Operation of a Continuous Flow, Micro-Electroporation System with Permeabilization Detection
10:34

The Fabrication and Operation of a Continuous Flow, Micro-Electroporation System with Permeabilization Detection

Published on: January 7, 2022

3.5K

Area of Science:

  • Biomedical Engineering
  • Electrical Engineering
  • Wireless Communication

Background:

  • Wireless systems are increasingly vital for bio-implantable devices like pacemakers and cochlear implants.
  • Efficient power transfer and data transmission are crucial for these devices, relying on inductive coupling and power amplifiers.
  • Device efficiency is influenced by circuit design, load variations, and coil coupling in radio frequency (RF) systems.

Purpose of the Study:

  • To provide a comprehensive survey of power amplifier classes and controller techniques used in bio-implantable devices.
  • To analyze the characteristics, efficiency, and performance of various automatic frequency controller (AFC) methods.
  • To identify current challenges and suggest future research directions for AFCs in implanted systems.

Main Methods:

  • A comprehensive review of existing literature on power amplifier classes and controller techniques for bio-implants.
  • Detailed investigation and summarization of AFC techniques, including gate drive switching, closed-loop power control, and microcontroller-based frequency control.
  • Analysis of key parameters such as carrier frequency, power efficiency, coil displacement, power consumption, and supply voltage for different controllers.

Main Results:

  • Various AFC techniques, including gate drive switching control and closed-loop power control, are effective in maintaining stable resonance frequency for transcutaneous power transfer.
  • Detailed data on carrier frequency, power efficiency, coil displacement, power consumption, supplied voltage, and CMOS chip implementations are presented in tables.
  • Existing AFC technologies are generally capable but not yet optimal for the demanding requirements of implantable devices.

Conclusions:

  • Current automatic frequency controller technologies show promise but require further advancement to meet the needs of modern bio-implantable devices.
  • Future research should focus on developing low-power, highly efficient, high data rate, and reliable AFCs for enhanced performance of implanted systems.
  • Addressing challenges in controller design will be key to improving the overall functionality and reliability of wireless biomedical implants.